KS57C2308/P2308/C2316/P2316KS57P2308/P2316 OTP

Table 16-1. Pin Descriptions Used to Read/Write the EPROM

 

Main Chip

 

 

 

 

During Programming

 

 

 

 

 

 

 

 

 

 

 

Pin Name

Pin Name

 

Pin No.

 

I/O

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

VLC1

SDAT

10

 

I/O

 

Serial data pin. Output port when reading and

 

 

 

 

 

 

 

 

input port when writing can be assigned as

 

 

 

 

 

 

 

 

Input/push-pull output port respectively.

 

 

 

 

 

 

 

 

 

 

 

VLC2

SCLK

11

 

I/O

 

Serial clock pin. Input only pin.

 

TEST

VPP (TEST)

16

 

I

 

Power supply pin for EPROM cell writing

 

 

 

 

 

 

 

 

(indicates that OTP enters into the writing mode).

 

 

 

 

 

 

 

 

When 12.5 V is applied, OTP is in writing mode

 

 

 

 

 

 

 

 

and when 5 V is applied, OTP is in reading mode.

 

 

 

 

 

 

 

 

(Option)

 

 

 

 

 

 

 

 

 

 

 

 

RESET

RESET

19

 

I

 

Chip initialization

 

 

 

 

 

 

 

 

 

 

 

VDD / VSS

VDD / VSS

12/13

 

I

 

Logic power supply pin. VDD should be tied to +5

 

 

 

 

 

 

 

 

V during programming.

 

 

 

 

 

 

 

 

 

Table 16-2. Comparison of KS57P2308/P2316 and KS57C2308/C2316 Features

 

 

 

 

 

 

 

Characteristic

 

 

KS57P2308/P2316

KS57C2308/C2316

 

 

 

 

 

 

 

 

Program Memory

 

 

8 K/16 K-byte EPROM

 

8 K/16-Kbyte mask ROM

 

 

 

 

 

 

 

Operating Voltage (VDD)

 

1.8 V to 5.5 V

 

1.8 V to 5.5 V

 

OTP Programming Mode

 

VDD = 5 V, VPP (TEST) = 12.5 V

 

Pin Configuration

 

 

80 QFP

 

 

 

 

80 QFP

 

 

 

 

 

 

 

EPROM Programmability

 

User Program 1 time

 

Programmed at the factory

 

 

 

 

 

 

 

 

 

 

OPERATING MODE CHARACTERISTICS

When 12.5 V is supplied to the Vpp (TEST) pin of the KS57P2308/P2316, the EPROM programming mode is entered. The operating mode (read, write, or read protection) is selected according to the input signals to the pins listed in Table 16-3 below.

Table 16-3. Operating Mode Selection Criteria

VDD

Vpp

REG/

Address

R/W

Mode

 

(TEST)

MEM

(A15-A0)

 

 

 

 

 

 

 

 

5 V

5 V

0

0000H

1

EPROM read

 

 

 

 

 

 

 

12.5V

0

0000H

0

EPROM program

 

 

 

 

 

 

 

12.5V

0

0000H

1

EPROM verify

 

 

 

 

 

 

 

12.5V

1

0E3FH

0

EPROM read protection

 

 

 

 

 

 

NOTE: "0" means low level; "1" means high level.