3RECORD SET

2 Turn the jog dial to select “2. RECORDING AREA SET” from the <RECORD SET> screen, and then turn the shuttle dial clockwise.

The <RECORDING AREA SET> screen is displayed.

3 Turn the jog dial to select “AREA FULL RESET”, and then turn the shuttle dial clockwise.

“NO” on the <WARNING> screen flashes.

Flashing

4 Turn the jog dial to select “YES”, and then turn the shuttle dial clockwise.

“NORMAL RECORDING AREA” is set to the single overwrite condition.

5 Use the same procedure to make settings for the “ALARM RECORDING AREA”.

6 Press the [EXIT] button.

The setting procedure is ended and the display returns to the normal screen.

EXIT

zTo perform overwriting automatically, set “OVERWRITE” for either “NORMAL RECORDING AREA” or “ALARM RECORDING AREA” from <RECORDING CONDITIONS SET> screen to “ON”. (JP.60)

zWhenever “AREA FULL RESET” is performed for “NORMAL RECORDING AREA” or “ALARM RECORDING AREA”, the video recorded in the corresponding area will be overwritten.

zImages in the archive area are erased when “AREA FULL RESET” is performed for the archive area.

Setting recording conditions

Use the following setting procedure to indicate whether overwriting is to be performed (deleting old video) or recording is to be stopped when any of the hard disk’s recording areas become full. In the latter case, the remaining capacity is shown as a percentage on the operation display area.

Setting normal recording area overwriting and displaying the remaining capacity on the operation display area

1 Turn the jog dial to select “OVERWRITE” for normal recording area, and then turn the shuttle dial clockwise.

“ON” flashes.

SETTINGS