3RECORD SET

5 Turn the jog dial to change “OFF” to “ON”, and then turn the shuttle dial clockwise.

The cursor moves to line 1.

EXT

***** *****

OFF

5FPS ON

6 Press the [EXIT] button.

The setting is completed and turns to normal screen.

EXIT

7 Press the [TIMER] button.

TIMER

zThe [TIMER] button lights up and the recorder enters timer recording standby mode.

z“REC” will be displayed within the operation display area while a signal is being received (with a pulse width of 1 second or more) via the EXT TIMER ON terminal, and monitoring video will be recorded in the normal recording area.

zExternal timer recording and normal timer recording can be combined.

zConnect the signal line from the external timer to the external timer recording terminal. External timer recording will not be possible until a timer is connected.

Setting alarm recording

To set alarm recording

Use the following procedure to select the recording picture quality, audio recording, and recording rate for the alarm recording area.

1 Press the [MENU] button and turn the jog dial to select “2. RECORD SET”, and then turn the shuttle dial clockwise.

The <RECORD SET> screen is displayed.

MENU

2 Turn the jog dial to select “7. ALARM REC MODE SET”, and then turn the shuttle dial clockwise.

The <ALARM REC MODE SET> screen is displayed.

The cursor moves to

“ALARM

RECORDING”.

3

Turn the shuttle dial clockwise.

 

“OFF” flashes.

 

 

4

dial clockwise.

SETTINGS

Turn the jog dial to select “ALARM

 

RECORDING”, and then turn the shuttle

[Settings] (‹ indicates the default setting)

Setting

Description

 

 

‹OFF

Alarm recording is not carried out.

 

 

 

Alarm recording is always carried out,

ENABLED

regardless of whether or not timer recording

 

is being performed.

 

 

AL-REC ON

Alarm recording is carried out only during

TIMER

timer recording.

 

 

AL-REC OFF

Alarm recording is carried out only when

TIMER

timer recording is not being performed.

 

 

OLY AL-RC

Alarm recording is carried out only for the

amount of time set by the timer. Normal

ON TMR

recording is not performed.

 

 

 

“OLY AL-RC ON TMR” can be validated simply by making a timer setting. Accordingly, there is no need to press the [TIMER] button.

The following settings are carried out using the shuttle dial and jog dial.

zVertical cursor movement: Turn the jog dial.

zCursor movement to the right: Turn the shuttle dial clockwise.

zModification of values: Turn the shuttle dial clockwise, and then with the setting value flashing, turn the jog dial.

zConfirmation of values: Turn the shuttle dial clockwise.