3RECORD SET

zAll sensors on the same line as the cursor can be modified simultaneously by pressing the [MENU RESET] button. (A B -)

8 Turn the jog dial to move the cursor to “T-1”, and then turn the shuttle dial clockwise.

“T-1” flashes.

9 Turn the jog dial to select T-1, T-2, T-3, or T-4, and then turn the shuttle dial clockwise.

The cursor moves to “LEVEL”.

10 Turn the shuttle dial clockwise.

“OFF” flashes for “LEVEL”.

11 Turn the jog dial to set the sensitivity (OFF or 1 through 10), and then turn the shuttle dial clockwise.

The cursor moves to “MODE”.

[Settings] (‹ indicates the default setting)

Setting

Description

 

 

‹OFF

Motion sensing is not carried out.

 

 

1 to10

Motion sensing is carried out. Lower values

correspond to higher sensitivities.

 

 

 

12 Turn the shuttle dial clockwise.

“A” flashes for the “MODE”.

13 Turn the jog dial to select a “MODE”, and then turn the shuttle dial clockwise.

The mode selection is confirmed and the cursor returns to the top left position.

[Settings] (‹ indicates the default setting)

Setting

Description

‹A

The motion sensor alarm is triggered when a

moving object is detected in A.

 

BThe motion sensor alarm is triggered when a moving object is detected in B.

 

The motion sensor alarm is triggered when a

A AND B

moving object is detected by a sensor in both A

 

and B.

 

 

 

By setting A to important points (or suspected

 

points of motion) and setting B to non-moving

A AND NB

points, motion can be detected at point A even

when the overall brightness changes and in other

 

situations where motion at both A and B would

 

normally be detected.

 

 

 

The motion sensor alarm is triggered when an

A TO B

object is detected moving from A to B. (within 2

 

seconds from A to B)

 

 

 

The motion sensor alarm is triggered when an

B TO A

object is detected moving from B to A. (within 2

 

seconds from B to A)

 

 

 

A motion sensor alarm is triggered when the

 

entire image changes uniformly. In this way,

Csprays and other similar measures can be protected against. (No sensor settings are needed for this mode.)

14 Set “LEVEL” and “MODE” for T-2 through T-4 using the same procedure (i.e., steps 8 through 13).