3RECORD SET

2 Turn the jog dial to select “5. PROGRAM REC SET”, and then turn the shuttle dial clockwise.

The <PROGRAM REC SET> screen is displayed with the cursor positioned on “PROGRAM”.

3 Turn the shuttle dial clockwise.

“P-1” flashes.

4 Turn the jog dial to select a program number (P-1, for example), and then turn the shuttle dial clockwise.

The cursor moves to “01” from “SERECT INDIVIDUAL CAMERA RATE (FPS)”.

5 Turn the shuttle dial clockwise.

“1” (recording rate) flashes.

6 Turn the jog dial to select a recording rate (3.75, for example), and then turn the shuttle dial clockwise.

Camera No. 1 is now set to record at a rate of 3.75. The cursor moves to “02”.

Valid recording rates

30*, 15, 7.5, 3.75, 1.875, 1.0, 0.500, 0.330, 0.250, 0.200, 0.100, 0.050, 0.033 (Unit: FPS)

*A selection cannot be made when pre-alarm recording has been set to “ON”.

7 Set recording rates for Camera No. 2 and Camera No. 3 in the same way.

8 With the cursor flashing on “04” (camera number), turn the jog dial to select “OFF”, and then turn the shuttle dial clockwise.

Video from Camera No. 4 will not be recorded.

9 Use the same procedure to set Camera No. 5 and Camera No. 6 to “OFF”.

10 If necessary, use this procedure to setup other programs (i.e., No. 2 through No. 4).

11 Press the [EXIT] button.

The setting procedure is ended and the display returns to the normal screen.