Dell R300 owner manual Troubleshooting a SCSI Tape Drive

Models: R300

1 184
Download 184 pages 39.19 Kb
Page 141
Image 141
Troubleshooting a SCSI Tape Drive

9Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem is not resolved, see "Getting Help" on page 165.

Troubleshooting a SCSI Tape Drive

Problem

Defective tape drive

Defective tape cartridge

Missing or corrupted tape-backup software or tape drive device driver

Defective SCSI controller

Action

1Remove the tape cartridge you were using when the problem occurred, and replace it with a tape cartridge that you know works.

2Ensure that the SCSI device drivers for the tape drive are installed and are configured correctly. See "Optical Drive" on page 79.

3Reinstall the tape-backup software as instructed in the tape-backup software documentation.

4Ensure that the tape drive’s interface/DC power cable is connected to the tape drive and SCSI controller card.

5Verify that the tape drive is configured for a unique SCSI ID number and that the tape drive is terminated or not terminated, based on the interface cable used to connect the drive.

See the documentation for the tape drive for instructions on selecting the SCSI ID number and enabling or disabling termination.

6Run the appropriate online diagnostics tests. See "Using Dell PowerEdge Diagnostics" on page 151.

7Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

Troubleshooting Your System

141

Page 141
Image 141
Dell R300 owner manual Troubleshooting a SCSI Tape Drive