Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1211

ROMB Batt

RAID battery is either

Reseat the RAID battery

 

 

missing, bad, or unable to

connector. See

 

 

recharge due to thermal

"Troubleshooting a SAS or

 

 

issues.

SAS RAID Controller" on

 

 

 

page 145, and

 

 

 

"Troubleshooting System

 

 

 

Cooling Problems" on

 

 

 

page 134.

E1214

## PwrGd

Specified voltage regulator

See "Getting Help" on

 

 

has failed.

page 165.

E1215

## PwrGd

Specified voltage regulator

See "Getting Help" on

 

 

has failed.

page 165.

E1226

PCI Rsr 1.5V

1.5V Riser Card Power Good

See "Getting Help" on

 

PwrGd

failure.

page 165.

E1229

CPU # VCORE

Processor # VCORE voltage

See "Getting Help" on

 

 

regulator has failed.

page 165.

E122A

CPU VTT PwrGd Processor # VTT voltage has

See "Getting Help" on

 

 

exceeded the allowable

page 165.

 

 

voltage range

 

E1310

RPM Fan ##

RPM of specified cooling

See "Troubleshooting

 

 

fan is out of acceptable

System Cooling

 

 

operating range.

Problems" on page 134.

E1311

FAN MOD ##

RPM of specified cooling

See "Troubleshooting

 

RPM

fan module is out of

System Cooling

 

 

acceptable operating range.

Problems" on page 134.

E1313

Fan

The system is no longer fan-

Check control panel LCD

 

Redundancy

redundant. Another fan

for additional scrolling

 

 

failure will put the system at

messages. See

 

 

risk of over-heating.

"Troubleshooting System

 

 

 

Cooling Problems" on

 

 

 

page 134.

24

About Your System

Page 24
Image 24
Dell R300 E1211 Romb Batt, E1214 ## PwrGd, E1215 ## PwrGd, E1226 PCI Rsr, E1229, E122A, E1310 RPM Fan ##, E1311, E1313 Fan