Any of these actions will remove fault messages, and return the status indicators and LCD colors to the normal state. Messages will reappear under the following conditions:

The sensor returns to a normal state but fails again, resulting in a new SEL entry.

The system is reset and new error events are detected.

A failure is recorded from another source that maps to the same display entry.

System Messages

System messages appear on the screen to notify you of a possible problem with the system. Table 1-3 lists the system messages that can occur and the probable cause and corrective action for each message.

NOTE: If you receive a system message that is not listed in Table 1-3, check the documentation for the application that is running when the message appears or the operating system's documentation for an explanation of the message and recommended action.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the computer, and protecting against electrostatic discharge.

Table 1-7. System Messages

Message

Causes

Corrective Actions

 

 

 

Alert! DIMM1_A and

If more than one DIMM

Check other system

DIMM1_B must be

is present, DIMMs must

messages for additional

populated with a

be installed in matching

information for possible

matched set of

pairs.

causes. For memory

DIMMs if more than

 

configuration information,

one DIMM is

 

see "Memory Module

present. The

 

Installation Guidelines" on

following memory

 

page 102. If the problem

DIMMs have been

 

persists, see

disabled:

 

"Troubleshooting System

 

 

Memory" on page 135.

34

About Your System

Page 34
Image 34
Dell R300 owner manual System Messages