Table 1-7. System Messages (continued)

Message

Causes

Corrective Actions

Unsupported RAID The RAID key installed in Information only.

key detected. the system is not supported on this system.

Utility partition

The <F10> key was

not available

pressed during POST, but

 

no utility partition exists

 

on the boot hard drive.

Warning: A fatal

A fatal system error

error has caused

occurred and caused the

system reset!

system to reboot.

Please check the

 

system event log!

 

Create a utility partition on the boot hard drive. See the CDs that came with your system.

Check the SEL for information that was logged during the error. See the applicable troubleshooting section in "Troubleshooting Your System" on page 123 for any faulty components specified in the SEL.

Warning! No micro

Microcode update failed.

Update the BIOS firmware.

code update loaded

 

See "Getting Help" on

for processor n

 

page 165.

Warning! Detected

RAID key or RAID DIMM

Information only.

missing RAID

missing when system is in

 

hardware for the

RAID mode.

 

embedded RAID

 

 

subsystem.

 

 

Warning! Detected

Embedded RAID

See "Using the System Setup

mode change from

subsystem configuration

Program" on page 46.

SCSI to RAID on

has changed in System

 

channel x of the

Setup.

 

embedded RAID

 

 

subsystem.

 

 

Warning! Detected

Embedded RAID

See "Using the System Setup

mode change from

subsystem configuration

Program" on page 46.

RAID to SCSI on

has changed in System

 

channel x of the

Setup.

 

embedded RAID

 

 

subsystem.

 

 