Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1712

PCI SERR B##

The system BIOS has

Remove and reseat the

 

D## F##

reported a PCI system error

PCIe expansion cards. If

 

 

on a component that resides

the problem persists, see

 

 

in PCI configuration space

"Troubleshooting

 

 

at bus ##, device ##,

Expansion Cards" on

 

 

function ##.

page 147.

PCI SERR Slot The system BIOS has

#

reported a PCI system error

 

on a component that resides

 

in the specified slot.

Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 147.

E1714 Unknown Err The system BIOS has

See "Getting Help" on

determined that there has

page 165.

been an error in the system,

 

but is unable to determine

 

its origin.

 

E171F PCIE Fatal

The system BIOS has

Err B## D##

reported a PCIe fatal error

F##

on a component that resides

 

in PCIe configuration space

 

at bus ##, device ##,

 

function ##.

Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 147.

PCIE Fatal The system BIOS has Err Slot # reported a PCIe fatal error

on a component that resides in the specified slot.

Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 147.

E1810 HDD ## Fault The SAS subsystem has

See "Troubleshooting a

determined that hard drive

Hard Drive" on page 142.

## has experienced a fault.

 