Dell R300 owner manual 6. LCD Status Messages continued

Models: R300

1 184
Download 184 pages 39.19 Kb
Page 31
Image 31
Manual background

Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E2018

Prog Timer

Programmable interval

See "Getting Help" on

 

 

timer error.

page 165.

E2019

Parity Error

Parity error.

See "Getting Help" on

 

 

 

page 165.

E201A

SIO Err

SIO failure.

See "Getting Help" on

 

 

 

page 165.

E201B

Kybd

Keyboard controller failure.

See "Getting Help" on

 

Controller

 

page 165.

E201C

SMI Init

System management

See "Getting Help" on

 

 

interrupt (SMI)

page 165.

 

 

initialization failure.

 

E201D

Shutdown Test BIOS shutdown test failure.

See "Getting Help" on

 

 

 

page 165.

E201E

POST Mem Test BIOS POST memory test

See "Troubleshooting

 

 

failure.

System Memory" on

 

 

 

page 135. If problem

 

 

 

persists, see "Getting

 

 

 

Help" on page 165.

E201F DRAC Config Dell remote access controller (DRAC) configuration failure.

Check screen for specific error messages.

Ensure that DRAC cables and connectors are properly seated. If problem persists, see your DRAC documentation.

E2020

CPU Config

CPU configuration failure.

Check screen for specific

 

 

 

error messages.

E2021

Memory

Incorrect memory

Check screen for specific

 

Population

configuration. Memory

error messages. See

 

 

population order incorrect.

"Troubleshooting System

 

 

 

Memory" on page 135.

E2022

POST Fail

General failure after video.

Check screen for specific

 

 

 

error messages.

About Your System

31

Page 31
Image 31
Dell R300 owner manual 6. LCD Status Messages continued