Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E161C

PS # Input

Power source for specified

Check the AC power

 

Lost

power supply is unavailable,

source for the specified

 

 

or out of acceptable range.

power supply. If the

 

 

 

problem persists, see

 

 

 

"Troubleshooting Power

 

 

 

Supplies" on page 133.

E1624

PS Redundancy The power supply subsystem

See "Troubleshooting

 

 

is no longer redundant. If

Power Supplies" on

 

 

the last supply fails, the

page 133.

 

 

system will go down.

 

E1710

I/O Channel

The system BIOS has

See "Getting Help" on

 

Chk

reported an I/O channel

page 165.

 

 

check.

 

E1711 PCI PERR B##

The system BIOS has

D## F##

reported a PCI parity error

 

on a component that resides

 

in PCI configuration space

 

at bus ##, device ##,

 

function ##.

Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 147.

PCI PERR Slot The system BIOS has

#

reported a PCI parity error

 

on a component that resides

 

in the specified PCIe slot.

Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 147.