Dell R300 owner manual PCIe Fatal Error

Models: R300

1 184
Download 184 pages 39.19 Kb
Page 39
Image 39
PCIe Fatal Error

Table 1-7. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

PCIe Fatal Error

PCI Express fatal errors

Reseat the PCIe card in the

caused a system

occurred during the

specified slot number. See

reset: Slot X

previous boot.

"Installing an Expansion

Embedded

 

Card" on page 95. If the

 

problem persists, see

Bus#XX/Dev#XX/Func

 

 

"Getting Help" on page 165.

X

 

 

 

Please check the

 

 

system event log

 

 

for details

 

 

Plug & Play

Error encountered in

Install the NVRAM_CLR

Configuration Error initializing PCIe device;

jumper and reboot the

 

faulty system board.

system. See Figure 6-1 for

 

 

jumper location. If the

 

 

problem persists, see

"Troubleshooting Expansion Cards" on page 147.

Read fault

Requested sector not found

The operating system cannot read from the hard drive or USB device, the system could not find a particular sector on the disk, or the requested sector is defective.

Replace the USB medium or device. Ensure that the USB or hard drive cables are properly connected. See "Troubleshooting a USB Device" on page 127, "Troubleshooting an Internal USB Key" on page 137, and "Troubleshooting a Hard Drive" on page 142.

Remote

System unable to process Retry Remote Configuration.

configuration

Remote Configuration

update attempt

request.

failed

 