Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1811

HDD ## Rbld

The specified hard drive has

See "Troubleshooting a

 

Abrt

experienced a rebuild abort.

Hard Drive" on page 142.

 

 

 

If the problem persists,

 

 

 

see your RAID

 

 

 

documentation.

E1812

HDD ##

The specified hard drive has

Information only.

 

Removed

been removed from the

 

 

 

system.

 

E1913 CPU &

The BMC firmware does not

Firmware

support the CPU.

Mismatch

 

Update to the latest BMC firmware. See the BMC User’s Guide for more information on setup and use of BMC.

E1A12

PCI Rsr

One or all of the PCIe risers

 

Config

is configured incorrectly,

 

 

preventing the system from

 

 

powering on.

E1A12

PCI Rsr

One or all of the PCIe risers

 

Missing

is missing, preventing the

 

 

system from powering on.

E1A14

SAS Cable A

SAS cable A is missing or

 

 

bad.

E1A15 SAS Cable B SAS cable B is missing or bad.

Reinstall the missing riser card(s).

Check that all connections are secure and correctly positioned.

Reseat the cable. If the problem persists, replace cable.

If the problem persists, see "Getting Help" on page 165.

Reseat the cable. If the problem persists, replace cable.

If the problem persists, see "Getting Help" on page 165.