Dell R300 owner manual 6. LCD Status Messages continued

Models: R300

1 184
Download 184 pages 39.19 Kb
Page 30
Image 30
Manual background

Table 1-6. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1A15

SAS Cable C

SAS cable C is missing or

Reseat the cable. If the

 

 

bad.

problem persists, replace

 

 

 

cable.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 165.

E1A18

PDB Ctrl

Control cable for the power

Reseat the cable. If the

 

Cable

distribution board (PDB) is

problem persists, replace

 

 

missing or bad

cable.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 165.

E2010

No Memory

No memory is installed in

Install memory. See

 

 

the system.

"Installing Memory

 

 

 

Modules" on page 104.

E2011

Mem Config

Memory detected, but is not

See "Troubleshooting

 

Err

configurable. Error detected

System Memory" on

 

 

during memory

page 135.

 

 

configuration.

 

E2012

Unusable

Memory is configured, but

See "Troubleshooting

 

Memory

not usable. Memory

System Memory" on

 

 

subsystem failure.

page 135..

E2013

Shadow BIOS

The system BIOS failed to

See "Troubleshooting

 

Fail

copy its flash image into

System Memory" on

 

 

memory.

page 135.

E2014

CMOS Fail

CMOS failure. CMOS RAM

See "Getting Help" on

 

 

not functioning properly.

page 165.

E2015

DMA

DMA controller failure.

See "Getting Help" on

 

Controller

 

page 165.

E2016

Int

Interrupt controller failure.

See "Getting Help" on

 

Controller

 

page 165.

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on

 

 

 

page 165.

30

About Your System

Page 30
Image 30
Dell R300 owner manual 6. LCD Status Messages continued