Sanyo DSR-3506P manual Setting alarm operation and display, „ To stop motion sensor recording

Models: DSR-3506P

1 112
Download 112 pages 54.62 Kb
Page 75
Image 75

3RECORD SET

zMotion sensor positions are common for T-1 through T-4, and different settings cannot be made.

15 Turn the shuttle dial counter-clockwise.

Motion sensor settings are confirmed and the <ALARM REC MODE SET> screen is displayed once again.

„To stop motion sensor recording

Set the sensitivity level from the motion sensor setting screen to “OFF”.

zThe period for “T-1” through “T-4” as set in step 9 changes to that of “TIME PERIOD A” or “TIME PERIOD B” on P.50.

zThe sensitivity level can be checked using the setting screen. When motion is detected, the sensor color changes from green to red, and a buzzer is sounded. If detection is too sensitive, an alarm can be triggered even by slight changes in lighting; accordingly, the sensitivity level should be set to match the camera location.

Setting alarm operation and display

1 Press the [MENU] button and turn the jog dial to select “2. RECORD SET”, and then turn the shuttle dial.

The <RECORD SET> screen is displayed.

MENU

2 Turn the jog dial to select “8. ALARM OPERATION SET”, and then turn the shuttle dial clockwise.

The <ALARM OPERATION SET> screen is displayed with the cursor positioned on “ALARM RETRIGGER”.

3

Turn the shuttle dial clockwise.

 

 

“OFF” flashes in the “ALARM RETRIGGER” field.

SETTINGS

 

4

Turn the jog dial to set the alarm trigger

 

 

to “ON”, and then turn the shuttle dial

 

 

clockwise.

 

The cursor moves to “MAIN MON. DISPLAY”.

[Settings] (‹ indicates the default setting)

Setting

 

 

Description

 

 

 

 

 

 

 

 

 

 

Even if a new alarm is received on the same

‹OFF

channel during alarm recording, the duration is not

 

extended.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If a new alarm is received on the same channel

 

during alarm recording, the duration is extended and

 

both alarms are treated as one. (Example: Input in

 

the alarm sequence A B C) However, if the

 

new alarm is on a different channel, the alarms are

 

treated separately. (Example: Input in the alarm

 

sequence A B C)

ON

Example:

 

 

 

 

 

 

Alarm

 

 

Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

CH1

Alarm Recording A

Alarm Recording C

 

 

 

 

 

 

 

 

 

Alarm

 

 

 

 

 

 

 

 

 

 

CH2

 

Alarm Recording B

 

 

 

 

 

 

 

 

 

 

74

English

Page 75
Image 75
Sanyo DSR-3506P manual Setting alarm operation and display, „ To stop motion sensor recording, Example Alarm