3RECORD SET

5 Set “PICTURE QUALITY”.

[Settings] (‹ indicates the default setting)

Setting

Description

 

 

BASIC (BA)

15 kB

 

 

NORMAL (NO)

22 kB

 

 

‹ENHANCED(EN)

30 kB

 

 

FINE (FI)

42 kB

 

 

SUPER FINE (SF)

50 kB

 

 

zThe file size is intended as a general guideline and actual sizes will depend on the recorded video.

The maximum number of alarm recordings as determined by the alarm settings is displayed in parentheses.

Maximum number of alarm recordings

6 Set “AUDIO RECORDING”.

When set to “ON”, the letter “A (indicating that audio will be recorded)” is displayed in front of recording rate, and the maximum number of alarm recordings is displayed in parenthesis.

[Settings] (‹ indicates the default setting)

Setting

Description

 

 

‹OFF

Audio recording is not carried out.

 

 

ON

Audio recording is carried out.

 

 

[Setting conditions]

zAudio recording is possible when “REC RATE” is set to 1.00 FPS or greater.

7 SET “ALARM INTERLEAVE”

[Settings] (‹ indicates the default setting)

Setting

Description

SW

Recording is switched between camera video including

an alarm and video from all connected cameras.

 

‹ONLY

Video is recorded only from cameras with an alarm

occurring.

 

* Recording pattern for “SW” and “ONLY”

SW

 

Alarm

 

 

Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01

02

03

02

04

02

05

04

06

02

07

04

08

02

 

 

 

 

Alternate recording of multiple items of alarm video

ONLY

Alarm

 

 

Alarm is cancelled

 

 

 

 

 

 

 

 

 

 

 

 

01 02 03 02 02 02 02 02 04

Recording until the alarm is cancelled

8 Set “REC RATE” and “DURATION”

The maximum number of recording alarms (shown in parentheses) changes in accordance with the new settings.

(Default setting for recording rate: 15.00 FPS)

(Default setting for duration: 20 SEC)

Maximum number of alarm recording

[Settings]

 

 

Setting

Description

REC RATE

30.00 to 0.03 FPS

Sets the recording rate.

 

 

 

 

5 SEC, 10 SEC,

 

 

20 SEC, 40 SEC,

 

DURATION

1

MIN, 2 MIN,

Sets the recording time per

 

3

MIN, 4 MIN,

alarm.

 

5

MIN, 10 MIN,

 

 

15 MIN, CC*

 

* Operates while an alarm is being triggered. (5 sec. minimum)