3RECORD SET
5 Set “PICTURE QUALITY”.
[Settings] ( indicates the default setting)
Setting | Description |
|
|
BASIC (BA) | 15 kB |
|
|
NORMAL (NO) | 22 kB |
|
|
ENHANCED(EN) | 30 kB |
|
|
FINE (FI) | 42 kB |
|
|
SUPER FINE (SF) | 50 kB |
|
|
zThe file size is intended as a general guideline and actual sizes will depend on the recorded video.
The maximum number of alarm recordings as determined by the alarm settings is displayed in parentheses.
Maximum number of alarm recordings
6 Set “AUDIO RECORDING”.
When set to “ON”, the letter “A (indicating that audio will be recorded)” is displayed in front of recording rate, and the maximum number of alarm recordings is displayed in parenthesis.
[Settings] ( indicates the default setting)
Setting | Description |
|
|
OFF | Audio recording is not carried out. |
|
|
ON | Audio recording is carried out. |
|
|
[Setting conditions]
zAudio recording is possible when “REC RATE” is set to 1.00 FPS or greater.
7 SET “ALARM INTERLEAVE”
[Settings] ( indicates the default setting)
Setting | Description | |
SW | Recording is switched between camera video including | |
an alarm and video from all connected cameras. | ||
| ||
ONLY | Video is recorded only from cameras with an alarm | |
occurring. | ||
|
* Recording pattern for “SW” and “ONLY”
SW |
| Alarm |
|
| Alarm |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||||
01 | 02 | 03 | 02 | 04 | 02 | 05 | 04 | 06 | 02 | 07 | 04 | 08 | 02 |
|
|
|
| Alternate recording of multiple items of alarm video | |||||||||
ONLY | Alarm |
|
| Alarm is cancelled |
|
|
|
| |||||
|
|
|
|
|
|
|
|
01 02 03 02 02 02 02 02 04
Recording until the alarm is cancelled
8 Set “REC RATE” and “DURATION”
The maximum number of recording alarms (shown in parentheses) changes in accordance with the new settings.
(Default setting for recording rate: 15.00 FPS)
(Default setting for duration: 20 SEC)
Maximum number of alarm recording
[Settings]
|
| Setting | Description |
REC RATE | 30.00 to 0.03 FPS | Sets the recording rate. | |
|
|
| |
| 5 SEC, 10 SEC, |
| |
| 20 SEC, 40 SEC, |
| |
DURATION | 1 | MIN, 2 MIN, | Sets the recording time per |
| 3 | MIN, 4 MIN, | alarm. |
| 5 | MIN, 10 MIN, |
|
| 15 MIN, CC* |
|
* Operates while an alarm is being triggered. (5 sec. minimum)
English | 69 |