Sanyo DSR-3506P manual Canceling alarms, Setting alarm display, Cursor moves to Alarm Priority

Models: DSR-3506P

1 112
Download 112 pages 54.62 Kb
Page 76
Image 76

3RECORD SET

Setting alarm display

1 Turn the jog dial to select “MAIN MON. DISPLAY”, and then turn the shuttle dial clockwise.

“FULL” starts to flash for “MAIN MON. DISPLAY”.

[Settings] (‹ indicates the default setting)

Setting

Description

 

When an alarm is detected, the video on the

‹FULL

channel containing the alarm is displayed in full

 

screen format on the main monitor.

6When an alarm is detected, a multi-6 screen display is presented on the main monitor.

NC

The main monitor’s display does not change when

an alarm is detected.

 

2 Turn the jog dial to set “MAIN MON. DISPLAY”, and then turn the shuttle dial clockwise.

The cursor moves to “ALARM PRIORITY”.

3 Turn the shuttle dial clockwise and turn the jog dial to set “ALARM PRIORITY”, and then turn the shuttle dial clockwise once again.

The cursor moves to “MON.2 DISPLAY”.

[Settings] (‹ indicates the default setting)

Setting

Description

 

 

‹When a number of alarms are occurring, the most-

LAST recent alarm video is given priority.

 

When a number of alarms are occurring, only the

FIRST

video for the first alarm is displayed. However, if

the duration for the alarm with the first input

 

 

expires, video for the next alarm will be displayed.

 

 

 

When a number of alarms are occurring, the

SWITCH

display switches between the video from the

corresponding cameras, showing each for one

 

second.

zAfter an alarm duration has ended, the display returns to the screen prior to alarm input.

4 Turn the shuttle dial clockwise and turn the jog dial to set “MON.2 DISPLAY” (ON/OFF), and then turn the shuttle dial clockwise.

The cursor moves to “ALARM RETRIGGER”.

[Settings] (‹ indicates the default setting)

Setting

Description

 

 

ON

When an alarm occurs, the corresponding video is

displayed on the monitor 2.

 

 

 

‹OFF

No alarm video is displayed on the monitor 2.

 

 

5 Press the [EXIT] button.

The setting procedure is ended and the display returns to the normal screen.

EXIT

Canceling alarms

To forcibly cancel an alarm during alarm operation, press the [CAMERA SELECT] button for the camera inputting the alarm and hold it for approximately 3 seconds. Alternatively, connect a switch between the alarm reset terminal and C (the grounded terminal), and turn on the switch to cancel any alarm that is occurring.