Sanyo DSR-3506P manual Setting auto deleting, Turn the jog dial to select the storage period

Models: DSR-3506P

1 112
Download 112 pages 54.62 Kb
Page 62
Image 62

3RECORD SET

2 Turn the jog dial to select setting (OFF, for example), and then turn the shuttle dial clockwise.

“REMAINING DISK WARNING” changes to “1%” from “**”.

[Settings] (‹ indicates the default setting)

Setting

Description

 

 

‹OFF

Recording is stopped when the normal recording area

becomes full.

 

 

 

ON

Overwriting automatically starts from the beginning of

the normal recording area when it becomes full.

 

 

 

.

Remaining disk warning

zIf this is set to “OFF”, the FULL indicator or ALARM FULL indicator will start to flash when the remaining hard-disk capacity reaches the percentage set for

“REMAINING DISK WARNING”.

3 Use the same procedure to set “ALARM RECORDING AREA” to “OFF”.

4 Turn the jog dial to select “REMAINING DISK WARNING”, and then turn the shuttle dial clockwise.

5 Turn the jog dial to set a “REMAINING DISK WARNING”, and then turn the shuttle dial clockwise.

The remaining capacity can be set anywhere between 1% (default) and 10%.

6 Press the [EXIT] button.

The setting procedure is ended and the display returns to the normal screen.

EXIT

A warning will be displayed in the operation display area when the remaining capacity for any recording area reaches the specified percentage value. In addition, the FULL indicator (for the normal recording area) or the ALARM FULL indicator (for the alarm recording area) will flash at this time.

 

 

FULL indicator

ALARM FULL indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

Remaining

display area

 

 

capacity

 

 

 

 

display

 

 

 

 

 

 

 

 

01-01-04 00:00:00 REC 1%

EN A ALARM 0000

02

 

 

Setting auto deleting

You can set a storage period for recorded data as described below. When the set period has expired, the corresponding data will be automatically deleted.

1 Turn the jog dial to select “AUTO DELETE”, and then turn the shuttle dial clockwise.

“OFF” flashes.

2 Turn the jog dial to select the storage period.

You can set the storage period for recorded data “OFF“ or within a range of “1 DAY” - “99 DAYS” (full days).

English

61

Page 62