EXTERNAL SIGNAL

Unit 3: Installation

EXTERNAL SIGNAL

The external signal interface is designed to connect the printer to an applicator. Proceed to the printer’s Advanced Mode for various setup activities related to the external signal.

There are two connector types available for the external signal interface, one with a 14-pin connector and the other with a 25-pin connector.

 

 

SPECIFICATIONS

 

 

Signal Level

High: +2.4 to +5.0V, Low: +0.0 to +0.4V

 

 

Issuing/Reissuing EXT signal

Enable/Disable in the Advanced Mode.

 

 

Switching EXT signal

Switching jumper connector to enable +24V output by 24V and 27V power supplies.

 

When using 24V power supply: Short IN 24V side by jumper connector

 

When using 27V power supply: Short IN 27V side by jumper connector.

 

 

 

Signal Types

Type I

Print end signal (PREND) is “low” before printing labels, “high” after

 

 

completion of print, and “low” 20 miliseconds later.

 

Type II

Print end signal (PREND) is “high” before printing labels, “low” after

 

 

completion of print, and “high” 20 miliseconds later.

 

Type III

Print end signal (PREND) is “low” before printing labels, “high” from start to

 

 

end of print, and “low” upon completion of print.

 

Type IV

Print end signal (PREND) is “high” before printing labels, “low” from start to

 

 

end of print, and “high” upon completion of print.

 

 

 

14-PIN CONNECTOR ASSIGNMENTS

PIN

SIGNAL NAME

DIRECTION

LEVEL

MAX CURRENT

 

 

 

 

 

1

Paper End

Output

Low

5V, 400mA

2

Ground

--

--

--

3

Ribbon End

Output

High

5V, 400mA

4

Machine Error

Output

Low

5V, 400mA

5

Print Start (PRIN)

Input

Low

High: high impedance, Low: -15mAor more, 0V

6

Print End (PREND)

Output

Low

5V, 400mA

7

Reprint (PRIN2)

Input

Low

High: high impedance, Low: -15mAor more, 0V

8

EXT5V_IN

Input

 

5V

9

Online

Output

Low

5V, 400mA

10

Ribbon Near End

Output

Low

5V, 400mA

11

--

--

--

--

12

+24V

--

--

--

13

+5V

--

--

--

14

FG

--

--

--

 

 

 

 

 

Choose from Type I to Type IV for PREND (the output signal for Pin 6).