LOCAL AREA NETWORK (LAN) INTERFACE MODE (TABLE 4-8)

 

 

 

 

 

 

Unit 4: Printer Configuration

 

 

 

 

 

 

 

 

UNIVERSAL SERIAL BUS (USB) INTERFACE MODE (TABLE 4-7)

 

 

 

 

 

 

 

 

 

MENU

 

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

Communication Protocol. Selects the mode of Bi-Directional communications. In most cases this

 

 

 

 

 

menu does not need to be altered and is meant to help support legacy applications which may

 

 

 

 

 

have incorporated older bi-directional statuses. Anything other than Staus 5 or Standard (none) is

 

 

 

 

 

not recommended.

 

 

 

 

 

Status 5 - factory default. Most advanced of the options. This status is the most recent and

 

 

 

 

 

 

 

Comm. Protocol

 

 

represented in the interface specifications. For more information, refer to the appropriate

 

 

Status 5*

 

 

section in the programming and interface guide.

Standard - bi-directional interface is not used.

Status 2 - legacy bi-directional support. Not recommended for new applications.

Status 3 - legacy bi-directional support. Not recommended for new applications.

Status 4 - legacy bi-directional support. Not recommended for new applications. Is the menu selection screen for the USB Port option of the INTERFACES mode.

INTERFACES

Host Interface

 

 

Is the main menu screen for the Host Interface option of the INTERFACES mode. There are only

 

 

two options relative to the serial interface, ignore all others.

 

Host Interface

Auto Switching - the printer automatically switches to the relative interface type and moves

 

USB*

 

into the applicable menus.

 

 

USB - factory default. Allows the operator to select the interface and the relative menus will

 

 

 

 

 

follow.

 

 

 

 

 

Is a transitional screen that will allow the buffer size to be established in the following screen.

 

 

 

 

 

USB Port

 

 

 

Buffer Size in K

 

 

 

 

 

 

 

 

 

 

 

 

This menu configures the amount of memory allocated for the serial port buffer. The range is 1 to

 

 

16 Kbytes in 1 kbyte increments.

 

 

 

 

 

Buffer Size in K

Note: If a baud rate 19200 or greater is selected, the Buffer Size in K parameter may need to be

 

1 to 16KB*

 

increased from the default to 16 Kbytes to improve performance.

 

 

The factory default is 16.

 

 

 

 

 

 

 

This is the value used by the printer to time out from the current port and check the other selected

 

 

Port Types for data print. When the printer has not received data from the host after a certain

 

 

 

Timeout

 

period of time, it must timeout in order to service other ports.

 

10 sec*

 

The factory default of 10 seconds with an allowable range of 1 to 60 seconds.

 

 

 

 

 

 

LOCAL AREA NETWORK (LAN) INTERFACE MODE (TABLE 4-8)

 

 

 

 

 

 