Unit 4: Printer Configuration

 

 

 

 

 

 

 

 

 

CENTRONICS INTERFACE MODE (TABLE 4-6)

 

 

 

 

 

 

MENU

 

DESCRIPTION

 

 

 

 

 

 

 

Block-Check-Code Algorithm Check. Only available when Status 5 is selected for Bi-Com

 

 

 

interface. Determines how the printer will react if the BCC is set to be processed by the printer.

 

 

 

Disable - factory default. Does nothing regardless of whether the BCC is included in the

 

 

 

 

format.

 

BCC Check

 

 

 

Disable*

 

Cancel - errors when the incorrect BCC is being accessed. When the printer is broght back

 

 

 

 

online from an error, by pressing the Line key, the incorrect job is printed.

Resume - error when the incorrect item number is being accessed. When the printer is brought back online from the error, by pressing the Line key, the incorrect job is canceled.

 

 

The history buffer stores a history of printer statuses. Is only available when Status 5 is selected

 

 

for Bi-Com interface.

 

 

Temporary - factory default. Store the history buffer in the internal RAM. This memory is

 

History Buffer

 

Temporary*

 

deleted when the printer’s power is turned off.

 

 

Permanent - stores the history buffer in Flash (internal or optional) Memory. This memory

 

 

 

 

 

can only be cleared through the printer’s display.

 

 

 

 

 

Communication Protocol. Selects the mode of Bi-Directional communications. In most cases this

 

 

menu does not need to be altered and is meant to help support legacy applications which may

 

 

have incorporated older bi-directional statuses. Anything other than Staus 5 or Standard (none) is

 

 

not recommended.

 

 

Status 5 - factory default. Most advanced of the options. This status is the most recent and

 

 

 

represented in the interface specifications. For more information, refer to the appropriate

 

Comm. Protocol

 

 

Status 5*

 

section in the programming and interface guide.

 

 

Standard - bi-directional interface is not used.

 

 

 

 

Status 2 - legacy bi-directional support. Not recommended for new applications.

 

 

Status 3 - legacy bi-directional support. Not recommended for new applications.

 

 

Status 4 - legacy bi-directional support. Not recommended for new applications.

 

 

 

 

 

Is the main menu screen for the Host Interface option of the INTERFACES mode. There are only

 

 

two options relative to the serial interface, ignore all others.

 

Host Interface

Auto Switching - the printer automatically switches to the relative interface type and moves

 

Auto Switching*

 

into the applicable menus.

 

 

Centronics - factory default. Allows the operator to select the interface and the relative

 

 

 

 

 

menus will follow.

 

 

 

 

 

Is the menu selection screen for the Parallel Port option of the INTERFACES mode.

 

 

 

 

 

 

 

 

 

Parallel Port

 

 

 

Port Type

 

 

 

 

 

 

 

 

 

 

 

 

Is a submenu that allows the Centronics interface to be chosen.

 

 

 

 

 

 

 

 

 

Port Type

 

 

 

Centronics

 

 

 

 

 

 

 

 

 

 

 

 

Is a menu set that permits entry into the Data Bit 8 enable/disable menu.

 

 

 

 

 

 

 

 

 

CENTRONICS

 

 

 

Data Bit 8

 

 

 

 

 

 

GL408-412e Operator’s Manual