Section 5: Interface Specifications

5.15 MULTI JOB BUFFER (CONT’D)

3) Echo sequence

(2) Cancel Request Command

Host

ENQ (Status request command)

 

ID number = space

 

Status = Reception standby

STATUS

Printing amount = “000000”

Job name = space

PRINT

ID number =”12”

Printing amount =50

command

Job name =”SATO”

Printer

Receive, analyze, edit

ENQ (Status request command)

 

ID number =”12”

 

Status = printing

STATUS

Printing amount = “000050”

Job name = “SATO”

CAN (Cancel request command)

ACK (Printer Normal)

PRINT

ID number =”13”

Printing amount =100

command

Job name = “SATO”

ENQ (Status request command)

 

ID number = “13”

 

Status = printing

STATUS

Printing amount = “000100”

Job name = “SATO”

CAN (Cancel request command)

NAK (Printer Error)

ENQ (Status request command)

 

ID number = space

 

Status = Reception standby

STATUS

Printing amount = “000000”

Job name = space

Printing

First printing

Second printing

Third printing

Reception buffer cleared

Printing amount cleared

Receive, analyze, edit

Printing

First printing

Second printing

Paper End

Reception buffer cleared

During Paper

Printing amount cleared

End error.

Error cleared (pressing Start /

Stop key)