APPENDIX

Gradation

Scanning: 256

Printing: 2 value

 

 

 

Power supply

AC 120V, 60 Hz, 12A

 

 

Power consumption

Max. 1.4 kW

 

 

 

Overall dimensions

24-17/32" (W) x 24" (D) (623 mm (W) x 609.5 mm (D))

(with bypass tray folded)

 

 

 

 

Weight

Approx. 103.7 lbs. (47 kg) (Not includes toner cartridge)

 

 

Dimensions

24-17/32" (W) x 24" (D) x 30-15/16" (H)

(623mm (W) x 609.5mm (D) x 785.5mm (H))

 

 

 

Operating conditions

Temperature: 59°F to 86°F (15°C to 30°C), Humidity: 20% to 85%

 

 

 

Sound Power Level LwA(1B=10dB)

 

Copying: 6.3[B]

 

Standby: 3.6[B]

 

Sound Pressure Level LpA (bystander positions)

Noise level

Copying: 50[dB(A)]

Standby: 25[dB(A)]

 

 

Sound Pressure Level LpA (operator position)

 

Copying: 51[dB(A)]

 

Standby: 20[dB(A)]

 

Noise emission measurement in accordance with ISO 7779.

 

 

 

Emission concentration

Ozone:

0.02 mg/m3 or less

(measured according to

Dust:

0.075 mg/m3 or less

RAL-UZ62)

Styrene:

0.07 mg/m3 or less

*The first-copy time and warm-up time may vary depending on the power-supply voltage, ambient temperature, and other operating conditions.

Reversing single pass feeder (RSPF)

 

Weight

9 lbs. to 34 lbs. (35 g/m2 to 128 g/m2) (14 lbs. to 28 lbs. (52 g/m2 to 105 g/m2) for

 

 

Acceptable

two-sided original)

 

 

 

 

 

original

Size

5-1/2" x 8-1/2" to 11" x 17"

 

 

 

Capacity

Up to 100 sheets (Thickness 33/64" (13 mm) and below)

 

 

Detectable original sizes

5-1/2" x 8-1/2", 5-1/2" x 8-1/2"R, 8-1/2" x 11", 8-1/2" x 11"R, 8-1/2" x 14", 11" x 17"

 

 

(A4, A3)

 

 

 

 

 

 

Weight

16.6 lbs. (7.5 kg)

 

 

 

 

 

 

7

Dimensions

22-61/64" (W) x 17-9/64" (D) x 5-1/4" (H)

 

 

 

(586 mm (W) x 457 mm (D) x 145 mm (H))

 

 

 

 

 

 

 

 

 

 

 

As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification Note changes for product improvement without prior notice. The performance specification figures indicated are

nominal values of production units. There may be some deviations from these values in individual units.

81