28.10.96

1054K05.FM

Gigaset 1054, GBR: A30852-X954-B101-1-7619

Putting Into Service

Non-Cordless Devices

 

 

Connection Jacks

The Gigaset 1054 base station is equipped with two telephone jacks (B and C), for connecting non-cordless terminals. Internal station numbers are automatically allocated to the jacks:

Jack B (upper) has the internal station number 0

Jack C (lower) has the internal station number 9

The connections of the auxiliary devices must have TAE plugs. The Gigaset 1054 jacks have the code F/N.

Can be connected

Internal station no.

Register on system as

 

 

 

 

 

 

Telephones (Jack B or C)

0 or 9

Telephone

 

 

 

Answering machine (Jack B or C)

0 or 9

Telephone

 

 

 

Fax devices (Jack B)

0

Fax or “Neutral“

 

 

 

Modems (Jack B)

0

Modem

 

 

 

T-Online (VTX) devices (Jack B)

0

Modem

 

 

 

External bell (Jack B or C)

0 or 9

Telephone

 

 

 

Door interphone (Jack C)

9

Door interphone

 

 

 

Only approved non-cordless devices can be connected.

Connecting Telephones

Telephones can be connected immediately, without changing any settings. A telephone or non- cordless device does not have to be registered at the base station.

The dialing mode (pulse or tone dialing) is recognized automatically and does not need to be set. It is not possible to set up connections with two non-cordless devices simultaneously.

A signal key on the telephone has no function once the telephone is connected to Gigaset 1054 (exception: telephones with tone dialing).

The telephone does not display any call charges. Call charges are, however, recorded by the system. The charge sums per station and per multiple subscriber number can be queried or dele- ted from a registered mobile unit.

Connecting Non-Cordless Devices (other than telephones)

The settings necessary for the auxiliary device connection can be programmed using a registered mobile unit.

You can stipulate whether a fax device, modem, VTX, a door interphone or an answering machine is to be connected (see page 67 or page 116 ).

In addition, other station-specific settings, e.g. trunk authorization, call allocation, etc., can be programmed -- using a mobile unit -- for every connected auxiliary device.

When a fax device is used with Gigaset 1054, the fax must be set for operation behind a telecommunication system (see the operating instructions for your fax machine).

You can use the following Baud transmission rates on the station connections:

Jack B (upper), internal station number 0: up to 28,800 Baud Jack C (lower), internal station number 9: up to 9,600 Baud.

27

Page 33
Image 33
Siemens 1054 operating instructions Putting Into Service Non-Cordless Devices, Connection Jacks