Command Descriptions
2–306 TLS 216 Programmer Manual
TRIGger :MAIn SEQuence :
:STARt
:
LOW
X
<Space>
?
HIGH
AUXiliary
HIGH specifies that the AUX TRIGGER INPUT must be High relative to the
threshold level.
LOW specifies that the AUX TRIGGER INPUT must be Low relative to the
threshold level.
X specifies that the AUX TRIGGER INPUT can be either High or Low relative
to the threshold level.
TRIGGER:MAIN:SEQUENCE:START:AUXILIARY LOW
specifies that the AUX TRIGGER INPUT must be Low to meet the Boolean
requirements of the defined pattern for the main sequence trigger.
TRIGGER:MAIN:SEQUENCE:START:AUXILIARY?
might return HIGH, indicating the AUX TRIGGER INPUT must be High to
meet the Boolean requirements of the defined pattern for the main sequence
trigger.
TRIGger:MAIn:SEQuence:STARt:CH<x>Sets or queries the Boolean requirement (logic levels of High, Low, or Don’t
Care) for the selected channel for the main sequence trigger. The Boolean
requirements set for all the trigger inputs define the start logic pattern that the
logic scope recognizes.
Trigger
TRIGger:MAIn:SEQuence:STARt:CH<x> { HIGH | LOW|X} NOTE: defines
CH<x> pattern bit to High, Low or Don’t Care
TRIGger:MAIn:SEQuence:STARt:CH<x>?
Arguments
Examples
Group
Syntax