Recommended Operating Conditions (continued)

 

 

 

OPERATION

MIN

NOM

MAX

UNIT

 

 

 

 

 

 

 

 

 

 

 

S100 operation

 

 

±1.08

 

 

 

 

 

 

 

 

 

 

Receive input jitter

TPA, TPB cable inputs

S200 operation

 

 

±0.5

ns

 

 

 

S400 operation

 

 

±0.315

 

 

 

 

 

 

 

 

 

 

 

 

S100 operation

 

 

±0.8

 

 

 

 

 

 

 

 

 

 

Receive input skew

Between TPA and TPB cable inputs

S200 operation

 

 

±0.55

ns

 

 

 

S400 operation

 

 

±0.5

 

 

 

 

 

 

 

 

 

TA

Operating ambient temperature range

 

0

25

70

°C

TJ#

Virtual junction temperature

 

 

0

25

115

°C

Applies to external inputs and bidirectional buffers without hysteresis

Miscellaneous terminals are A03, B17, C15, C18, E05, E08, F19, H03, J01, J02, J03, J05, J06, J07, L02, L03, L05, M01, M02, M03, N01, N02, N13, P12, P15, R02, R17, T01 (A_CCDx, A_CDx, A_CVSx, A_VSx, B_CCDx, B_CDx, B_CVSx, B_VSx, SD_DAT0, SD_DAT2, SD_DAT3,

SD_CMD, SD_CLK, SD_DAT1, SM_CLE, SC_CD, SC_OC, SC_PWR_CTRL, CLK_48, SDA, SCL, DATA, LATCH, TEST0, CNA, SUSPEND, PHY_TEST_MA, and GRST terminals).

§ Applies to external output buffers

For a node that does not source power, see Section 4.2.2.2 in IEEE Std 1394a−2000.

#These junction temperatures reflect simulation conditions. The customer is responsible for verifying junction temperature. kMFUNC(0:6) share the same specifications as the PCI terminals.

14−3

Page 293
Image 293
Texas Instruments PCI7611, PCI7411, PCI7621, PCI7421 manual Tj#