14−3
Recommended Operating Conditions (continued)
OPERATION MIN NOM MAX UNIT
S100 operation ±1.08
Receive input jitter TPA, TPB cable inputs S200 operation ±0.5 ns
Receive input jitter
TPA, TPB cable inputs
S400 operation ±0.315
ns
S100 operation ±0.8
Receive input skew Between TPA and TPB cable inputs S200 operation ±0.55 ns
Receive input skew
Between TPA and TPB cable inputs
S400 operation ±0.5
ns
TAOperating ambient temperature range 0 25 70 °C
TJ# Virtual junction temperature 0 25 115 °C
Applies to external inputs and bidirectional buffers without hysteresis
Miscellaneous terminals are A03, B17, C15, C18, E05, E08, F19, H03, J01, J02, J03, J05, J06, J07, L02, L03, L05, M01, M02, M03, N01, N02,
N13, P12, P15, R02, R17, T01 (A_CCDx, A_CDx, A_CVSx, A_VSx, B_CCDx, B_CDx, B_CVSx, B_VSx, SD_DAT0, SD_DAT2, SD_DAT3,
SD_CMD, SD_CLK, SD_DAT1, SM_CLE, SC_CD, SC_OC, SC_PWR_CTRL, CLK_48, SDA, SCL, DATA, LATCH, TEST0, CNA, SUSPEND,
PHY_TEST_MA, and GRST terminals).
§Applies to external output buffers
For a node that does not source power, see Section 4.2.2.2 in IEEE Std 1394a−2000.
#These junction temperatures reflect simulation conditions. The customer is responsible for verifying junction temperature.
kMFUNC(0:6) share the same specifications as the PCI terminals.