Setting mode (08)

 

 

 

 

 

 

 

 

Default

 

 

 

Pro-

 

Classifi-

 

Func-

<Accept-

 

 

 

Code

Items

RAM

Contents

cedur

 

cation

 

tion

able

 

 

 

e

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

569

Image

Image quality closed-loop

ALL

8

M

Sets the fuser roller

1

 

control

control automatic start-up/

(color)

<0-20>

 

temperature to perform

 

 

 

Temperature setting of

 

 

 

closed-loop control

 

 

 

fuser roller at power-ON

 

 

 

when “1” or “2” (valid) is

 

 

 

 

 

 

 

set in 08-559.

 

 

 

 

 

 

 

0: 20°C

1: 25°C

 

 

 

 

 

 

 

2: 30°C

3: 35°C

 

 

 

 

 

 

 

4: 40°C

5: 45°C

 

 

 

 

 

 

 

6: 50°C

7: 55°C

 

 

 

 

 

 

 

8: 60°C

9: 65°C

 

 

 

 

 

 

 

10: 70°C

11: 75°C

 

 

 

 

 

 

 

12: 80°C

13: 85°C

 

 

 

 

 

 

 

14: 90°C

15: 95°C

 

 

 

 

 

 

 

16: 100°C 17: 105°C

 

 

 

 

 

 

 

18: 110°C 19: 115°C

 

 

 

 

 

 

 

20: 120°C

 

 

570

Image

Image quality closed-loop

ALL

4

M

Sets the relative humid-

1

 

control

control automatic start-up/

(color)

<0-6>

 

ity difference to per-

 

 

 

Relative humidity differ-

 

 

 

form the closed-loop

 

 

 

ence setting

 

 

 

control when “1” or “2”

 

 

 

 

 

 

 

(valid) is set in 08-565.

 

 

 

 

 

 

 

0: 0%

1: 5%

 

 

 

 

 

 

 

2: 10%

3: 15%

 

 

 

 

 

 

 

4: 20%

5: 25%

 

 

 

 

 

 

 

6: 30%

 

 

571

Image

Image quality closed-loop

ALL

4

M

Sets the period of time

1

 

control

control automatic start-up/

(color)

<0-24>

 

unattended to perform

 

 

 

Setting of period of time

 

 

 

closed-loop control

 

 

 

unattended

 

 

 

when “1” or “2” (valid) is

 

 

 

 

 

 

 

set in 08-566.

 

 

 

 

 

 

 

Setting value x 1 (hour)

 

572

Image

Image quality closed-loop

ALL

10

M

Sets the number of

1

 

control

control automatic start-up/

(color)

<0-30>

 

accumulated print vol-

 

 

 

Setting of accumulated

 

 

 

ume to perform closed-

 

 

 

print volume

 

 

 

loop control when “1” or

 

 

 

 

 

 

 

“2” (valid) is set in 08-

 

 

 

 

 

 

 

567.

 

 

 

 

 

 

 

 

Setting value x 100

 

 

 

 

 

 

 

(pages)

 

 

573

Image

Abnormality detection

ALL

0

M

Counts the abnormality

1

 

control

count (Y)

 

<0-16>

 

detection of image qual-

 

 

 

Display/0 clearing

 

 

 

ity control. Accumulat-

 

 

 

 

 

 

 

ing total of [CE10],

 

 

 

 

 

 

 

[CE20] and [CE40]

 

574

Image

Abnormality detection

ALL

0

M

Counts the abnormality

1

 

control

count (M)

 

<0-16>

 

detection of image qual-

 

 

 

Display/0 clearing

 

 

 

ity control. Accumulat-

 

 

 

 

 

 

 

ing total of [CE10],

 

 

 

 

 

 

 

[CE20] and [CE40]

 

575

Image

Abnormality detection

ALL

0

M

Counts the abnormality

1

 

control

count (C)

 

<0-16>

 

detection of image qual-

 

 

 

Display/0 clearing

 

 

 

ity control. Accumulat-

 

 

 

 

 

 

 

ing total of [CE10],

 

 

 

 

 

 

 

[CE20] and [CE40]

 

576

Image

Abnormality detection

ALL

0

M

Counts the abnormality

1

 

control

count (K)

 

<0-16>

 

detection of image qual-

 

 

 

Display/0 clearing

 

 

 

ity control. Accumulat-

 

 

 

 

 

 

 

ing total of [CE10],

 

 

 

 

 

 

 

[CE20] and [CE40]

 

e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE

 

 

 

© June 2005 TOSHIBA TEC

2 - 124

Page 124
Image 124
Toshiba 281C, 451C, 351C manual Ram