Adjustment mode (05)

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

Pro-

 

Classifi-

 

 

 

 

 

Func-

<Accept-

 

 

 

Code

 

Items

RAM

Contents

cedur

 

cation

 

 

 

 

 

tion

able

 

 

 

e

 

 

 

 

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

229-0

Transfer

 

2nd transfer

Single

ALL

144

M

When the value

14

 

 

 

roller bias out-

side

(black)

<0-187>

 

decreases, the 2nd

 

229-1

 

 

put adjust-

 

Reverse

ALL

119

M

transfer roller bias out-

14

 

 

 

ment

side at

(black)

<0-187>

 

put increases.

 

 

 

 

(Thick paper

duplexing

 

 

 

The adjustment value

 

 

 

 

1)

 

 

 

 

 

 

becomes effective

 

229-2

 

 

 

Single

ALL

125

M

14

 

 

 

 

when the Setting Mode

 

 

 

 

 

side

(color)

<0-187>

 

 

 

 

 

 

 

 

(08-544, 549 and 551)

 

229-3

 

 

 

 

Reverse

ALL

112

M

14

 

 

 

 

is 0 (invalid).

 

 

 

 

 

side at

(color)

<0-187>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

duplexing

 

 

 

 

 

 

230-0

Transfer

 

2nd transfer roller bias out-

ALL

153

M

When the value

14

 

 

 

put (Thick paper 2)

(black)

<0-187>

 

decreases, the 2nd

 

 

 

 

 

 

 

 

 

 

 

transfer roller bias out-

 

230-1

 

 

 

 

 

 

ALL

150

M

14

 

 

 

 

 

 

 

(color)

<0-187>

 

put increases.

 

 

 

 

 

 

 

 

 

 

 

The adjustment value

 

 

 

 

 

 

 

 

 

 

 

becomes effective

 

 

 

 

 

 

 

 

 

 

 

when the Setting Mode

 

 

 

 

 

 

 

 

 

 

 

(08- 544, 549 and 551)

 

 

 

 

 

 

 

 

 

 

 

is 0 (invalid).

 

231-0

Transfer

 

2nd transfer roller bias out-

ALL

131

M

When the value

14

 

 

 

put (Thick paper 3)

(black)

<0-187>

 

decreases, the 2nd

 

 

 

 

 

 

 

 

 

 

 

transfer roller bias out-

 

231-1

 

 

 

 

 

 

ALL

131

M

14

 

 

 

 

 

 

 

(color)

<0-187>

 

put increases.

 

 

 

 

 

 

 

 

 

 

 

The adjustment value

 

 

 

 

 

 

 

 

 

 

 

becomes effective

 

 

 

 

 

 

 

 

 

 

 

when the Setting Mode

 

 

 

 

 

 

 

 

 

 

 

(08- 544, 549 and 551)

 

 

 

 

 

 

 

 

 

 

 

is 0 (invalid).

 

232-0

Transfer

 

2nd transfer roller bias out-

ALL

119

M

When the value

14

 

 

 

put (OHP film)

 

 

(black)

<0-187>

 

decreases, the 2nd

 

 

 

 

 

 

 

 

 

 

 

transfer roller bias out-

 

232-1

 

 

 

 

 

 

ALL

119

M

14

 

 

 

 

 

 

 

(color)

<0-187>

 

put increases.

 

 

 

 

 

 

 

 

 

 

 

The adjustment value

 

 

 

 

 

 

 

 

 

 

 

becomes effective

 

 

 

 

 

 

 

 

 

 

 

when the Setting Mode

 

 

 

 

 

 

 

 

 

 

 

(08- 544, 549 and 551)

 

 

 

 

 

 

 

 

 

 

 

is 0 (invalid).

 

234-0

Transfer

 

2nd transfer

Single

ALL

5

M

Sets the offset amount

4

 

 

 

roller bias off-

side

(black)

<0-10>

 

of 2nd transfer roller

 

234-1

 

 

setting adjust-

 

Reverse

ALL

5

M

bias.

 

4

 

 

 

ment

side at

(black)

<0-10>

 

0: -500V 1: -400V

 

 

 

 

(Plain paper)

duplexing

 

 

 

2: -300V 3: -200V

 

 

 

 

 

 

 

 

 

 

 

4: -100V

5: 0V

 

234-2

 

 

 

 

Single

ALL

5

M

4

 

 

 

 

6: +100V

7: +200V

 

 

 

 

 

side

(color)

<0-10>

 

 

 

 

 

 

 

 

8: +300V

9: +400V

 

234-3

 

 

 

 

Reverse

ALL

5

M

4

 

 

 

 

10: +500V

 

 

 

 

 

 

side at

(color)

<0-10>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

duplexing

 

 

 

 

 

 

236-0

Transfer

 

2nd transfer

Single

ALL

5

M

Sets the offset amount

4

 

 

 

roller bias off-

side

(black)

<0-10>

 

of 2nd transfer roller

 

236-1

 

 

setting adjust-

 

Reverse

ALL

5

M

bias.

 

4

 

 

 

ment (Thick

side at

(black)

<0-10>

 

0: -500V 1: -400V

 

 

 

 

paper 1)

duplexing

 

 

 

2: -300V 3: -200V

 

 

 

 

 

 

 

 

 

 

 

4: -100V

5: 0V

 

236-2

 

 

 

 

Single

ALL

5

M

4

 

 

 

 

6: +100V

7: +200V

 

 

 

 

 

side

(color)

<0-10>

 

 

 

 

 

 

 

 

8: +300V

9: +400V

 

236-3

 

 

 

 

Reverse

ALL

5

M

4

 

 

 

 

10: +500V

 

 

 

 

 

 

side at

(color)

<0-10>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

duplexing

 

 

 

 

 

 

© June 2005 TOSHIBA TEC

 

 

 

 

e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE

2

2 - 43

Page 43
Image 43
Toshiba 281C, 451C, 351C manual +100V +200V Side Color +300V +400V 234-3 Reverse