Setting mode (08)
|
|
|
| Default |
|
| Pro- |
| Classifi- |
| Func- | <Accept- |
|
| |
Code | Items | RAM | Contents | cedur | |||
| cation |
| tion | able |
|
| e |
|
|
|
| value> |
|
| |
|
|
|
|
|
|
| |
1382 | Image | Fuser roller energy saving | ALL | 0 | M | Counts up the heater | 2 |
| process- | temperature time accumu- |
| <8 digits> |
| control time accumu- |
|
| ing | lating counter Display/0 |
|
|
| lated (at energy saving |
|
|
| clearing |
|
|
| mode). When the |
|
|
|
|
|
|
| counter value of the |
|
|
|
|
|
|
| fuser belt is cleared, |
|
|
|
|
|
|
| this counter value is |
|
|
|
|
|
|
| also cleared in sync at |
|
|
|
|
|
|
| PM support mode. |
|
1385 | Image | Number of output pages | ALL | 0 | M | Counts up when the | 1 |
| process- | (Thick paper 1) |
| <8 digits> |
| registration sensor is |
|
| ing |
|
|
|
| ON. When the counter |
|
|
|
|
|
|
| value of the fuser belt is |
|
|
|
|
|
|
| cleared, this counter |
|
|
|
|
|
|
| value is also cleared in |
|
|
|
|
|
|
| sync at PM support |
|
|
|
|
|
|
| mode. |
|
1386 | Image | Number of output pages | ALL | 0 | M | Counts up when the | 1 |
| process- | (Thick paper 2) |
| <8 digits> |
| registration sensor is |
|
| ing |
|
|
|
| ON. When the counter |
|
|
|
|
|
|
| value of the fuser belt is |
|
|
|
|
|
|
| cleared, this counter |
|
|
|
|
|
|
| value is also cleared in |
|
|
|
|
|
|
| sync at PM support |
|
|
|
|
|
|
| mode. |
|
1387 | Image | Number of output pages | ALL | 0 | M | Counts up when the | 1 |
| process- | (Thick paper 3) |
| <8 digits> |
| registration sensor is |
|
| ing |
|
|
|
| ON. When the counter |
|
|
|
|
|
|
| value of the fuser belt is |
|
|
|
|
|
|
| cleared, this counter |
|
|
|
|
|
|
| value is also cleared in |
|
|
|
|
|
|
| sync at PM support |
|
|
|
|
|
|
| mode. |
|
1388 | Image | Number of output pages | ALL | 0 | M | Counts up when the | 1 |
| process- | (OHP film) |
| <8 digits> |
| registration sensor is |
|
| ing |
|
|
|
| ON. When the counter |
|
|
|
|
|
|
| value of the fuser belt is |
|
|
|
|
|
|
| cleared, this counter |
|
|
|
|
|
|
| value is also cleared in |
|
|
|
|
|
|
| sync at PM support |
|
|
|
|
|
|
| mode. |
|
1389 | Main | Main charger wire clean- | ALL | 0 | M | Does not count up | 1 |
| charger | ing counter display/0 clear- |
| <5 digits> |
| when cleaning is not |
|
|
| ing |
|
|
| effective. |
|
1390 | Paper | Feeding retry counter | ALL | 0 | M | Counts the number of | 1 |
| feeding | (upper drawer) |
| <8 digits> |
| times of the feeding |
|
|
|
|
|
|
| retry from the upper |
|
|
|
|
|
|
| drawer. |
|
1391 | Paper | Feeding retry counter | ALL | 0 | M | Counts the number of | 1 |
| feeding | (lower drawer) |
| <8 digits> |
| times of the feeding |
|
|
|
|
|
|
| retry from the lower |
|
|
|
|
|
|
| drawer. |
|
1392 | Paper | Feeding retry counter | ALL | 0 | M | Counts the number of | 1 |
| feeding | (PFP upper drawer) |
| <8 digits> |
| times of the feeding |
|
|
|
|
|
|
| retry from the PFP |
|
|
|
|
|
|
| upper drawer. |
|
| © June 2005 TOSHIBA TEC |