Setting mode (08)

 

 

 

 

 

 

 

 

 

Default

 

 

 

Pro-

 

Classifi-

 

 

Func-

<Accept-

 

 

 

Code

 

Items

RAM

 

Contents

cedur

 

cation

 

 

tion

able

 

 

 

e

 

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

 

615

General

 

Size information of main

ALL

-

SYS

Displays the sizes of

2

 

 

 

memory and page memory

 

 

 

the main memory and

 

 

 

 

 

 

 

 

page memory. Enables

 

 

 

 

 

 

 

 

to check if each mem-

 

 

 

 

 

 

 

 

ory is properly recog-

 

 

 

 

 

 

 

 

nized.

 

616

Counter

 

Counting method in Twin

ALL

JPN: 1

SYS

Sets the counting

1

 

 

 

Color Mode

 

UC: 0

 

method in Twin Color

 

 

 

 

(Limitation Function)

 

EUR: 0

 

Mode with the Limita-

 

 

 

 

 

 

<0-1>

 

tion Function.

 

 

 

 

 

 

 

 

0: Count as color

 

 

 

 

 

 

 

 

1: Count as black

 

617

User

 

Print setting without

ALL

1

SYS

0:

Printed forcibly

1

 

interface

 

department code

 

<0-2>

 

1:

Not printed

 

 

 

 

 

 

 

 

2:

Deleted forcibly

 

618

User

 

Default setting of RADF

PPC

0

SYS

0:

Same size originals

1

 

interface

 

original size

 

<0-1>

 

1:

Mixed size originals

 

619

Paper

 

Time lag before auto-start

ALL

4

SYS

Sets the time taken to

1

 

feeding

 

of bypass feeding

 

<0-10>

 

add paper feeding

 

 

 

 

 

 

 

 

when paper in the

 

 

 

 

 

 

 

 

bypass tray has run out

 

 

 

 

 

 

 

 

during the bypass feed

 

 

 

 

 

 

 

 

copying.

 

 

 

 

 

 

 

 

0: Paper is not drawn

 

 

 

 

 

 

 

 

 

in unless the

 

 

 

 

 

 

 

 

 

[START] button is

 

 

 

 

 

 

 

 

 

pressed.

 

 

 

 

 

 

 

 

1-10: Setting value x

 

 

 

 

 

 

 

 

 

0.5sec.

 

620

User

 

Department management

PPC

1

SYS

0: Invalid

1

 

interface

 

setting (Copier)

 

<0-1>

 

1: Valid

 

621

User

 

Department management

FAX

1

SYS

0: Invalid

1

 

interface

 

setting (FAX)

 

<0-1>

 

1: Valid

 

622

User

 

Department management

PRT

1

SYS

0: Invalid

1

 

interface

 

setting (Printer)

 

<0-1>

 

1: Valid

 

623

User

 

Department management

SCN

1

SYS

0: Invalid

1

 

interface

 

setting (Scanner)

 

<0-1>

 

1: Valid

 

624

User

 

Department management

PRT

1

SYS

0: Invalid

1

 

interface

 

setting (List print)

 

<0-1>

 

1: Valid

 

625

User

 

Blank copying prevention

PPC

0

SYS

0: OFF

1

 

interface

 

mode during RADF jam-

 

<0-1>

 

1: ON (Start printing

 

 

 

 

ming

 

 

 

 

when the scanning

 

 

 

 

 

 

 

 

 

of each page is fin-

 

 

 

 

 

 

 

 

 

ished)

 

627

User

 

Rotation printing at the

ALL

0

SYS

0:

Not rotating

1

 

interface

 

nonsorting

 

<0-1>

 

1:

Rotating

 

628

User

 

Direction priority of original

PPC

0

SYS

0:

Automatic

1

 

interface

 

image

 

<0-1>

 

1:

Portrait

 

629

User

 

Department management

ALL

0

SYS

0:

Invalid

1

 

interface

 

setting

 

<0-1>

 

1:

Valid

 

632

User

 

Automatic calibration dis-

PPC

1

SYS

Sets the disclosing level

1

 

interface

 

closure level

 

<0-2>

 

of automatic calibration.

 

 

 

 

 

 

 

 

0:

Service technician

 

 

 

 

 

 

 

 

1:

Administrator

 

 

 

 

 

 

 

 

2: User

 

© June 2005 TOSHIBA TEC

 

e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE

2

2 - 127

Page 127
Image 127
Toshiba 281C, 451C, 351C manual Fax Sys