Adjustment mode (05)

 

 

 

 

 

 

 

 

Default

 

 

Pro-

 

Classifi-

 

 

 

 

 

Func-

<Accept-

 

 

Code

Items

 

 

RAM

Contents

cedur

 

cation

 

 

 

 

 

tion

able

 

 

e

 

 

 

 

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

 

 

1842-0

Transfer

Actual value

 

Intermedi-

ALL

153

M

Displays the value of

10

 

 

display of 2nd

 

ate level

(black)

<0-225>

 

2nd transfer roller bias

 

 

 

transfer roller

 

bias of

 

 

 

on the leading/trailing

 

 

 

bias

 

trailing

 

 

 

edge of paper when

 

 

 

of leading/

 

edge

 

 

 

printing is performed.

 

 

 

trailing

 

 

 

 

 

 

 

(The value corrected in

 

1842-1

 

 

 

Bias of

ALL

157

M

10

 

 

edge of paper

 

leading/

(black)

<0-225>

 

05-1839 is displayed.)

 

 

 

(Tab paper)

 

trailing

 

 

 

 

 

 

 

 

 

 

edge

 

 

 

 

 

1842-2

 

 

 

 

Intermedi-

ALL

150

M

 

10

 

 

 

 

 

ate level

(color)

<0-225>

 

 

 

 

 

 

 

 

bias of

 

 

 

 

 

 

 

 

 

 

trailing

 

 

 

 

 

 

 

 

 

 

edge

 

 

 

 

 

1842-3

 

 

 

 

Bias of

ALL

154

M

 

10

 

 

 

 

 

leading/

(color)

<0-225>

 

 

 

 

 

 

 

 

trailing

 

 

 

 

 

 

 

 

 

 

edge

 

 

 

 

 

1845-0

Transfer

2nd transfer roller bias

ALL

153

M

Displays the value of

10

 

 

actual value display

(black)

<0-187>

 

2nd transfer roller bias

 

 

 

(Tab paper)

 

 

 

 

 

when printing is oper-

 

1845-1

 

 

 

ALL

150

M

10

 

 

 

 

 

 

 

(color)

<0-187>

 

ated.

 

1847

Transfer

1st transfer roller bias

ALL

400

M

The drum surface

1

 

 

actual value display

 

<300-

 

potential at the 1st

 

 

 

(Tab paper)

 

 

 

800>

 

transfer bias resistance

 

 

 

 

 

 

 

 

 

 

 

detection control is

 

 

 

 

 

 

 

 

 

 

 

adjusted.

 

 

 

 

 

 

 

 

 

 

 

[Unit: V]

 

1848

Transfer

1st transfer bias resis-

ALL

-

M

The result value of the

2

 

 

tance detection control

 

<0-9999>

 

1st transfer bias resis-

 

 

 

Result value display

 

 

 

tance detection control

 

 

 

 

 

 

 

 

 

 

 

is displayed.

 

 

 

 

 

 

 

 

 

 

 

[Unit: V]

 

1849

Transfer

1st transfer roller bias out-

ALL

154

M

When the value

1

 

 

put adjustment

 

 

(black)

<0-225>

 

decreases, the 1st

 

 

 

 

 

 

 

 

 

 

 

transfer roller bias out-

 

 

 

 

 

 

 

 

 

 

 

put increases.

 

 

 

 

 

 

 

 

 

 

 

This setting is enabled

 

 

 

 

 

 

 

 

 

 

 

when "0" (disabled) is

 

 

 

 

 

 

 

 

 

 

 

set at the codes 08-

 

 

 

 

 

 

 

 

 

 

 

541, -549 and -551.

 

1850-0

Transfer

1st transfer

 

Y

ALL

138

M

When the value

4

 

 

roller bias out-

 

 

 

(color)

<0-225>

 

decreases, the 1st

 

1850-1

 

put adjust-

 

 

M

ALL

143

M

transfer roller bias out-

4

 

 

ment

 

 

 

(color)

<0-225>

 

put increases.

 

 

 

 

 

 

 

 

 

 

 

This setting is enabled

 

1850-2

 

 

 

 

C

ALL

154

M

4

 

 

 

 

when "0" (disabled) is

 

 

 

 

 

 

 

(color)

<0-225>

 

 

 

 

 

 

 

 

 

 

set at the codes 08-

 

1850-3

 

 

 

 

K

ALL

154

M

4

 

 

 

 

541, -549 and -551.

 

 

 

 

 

 

 

(color)

<0-225>

 

 

 

 

 

 

 

 

 

 

 

 

1861

Transfer

1st transfer roller

bias RMS

ALL

154

M

The RMS value of the

2

 

 

value display

 

 

(black)

<0-225>

 

1st transfer roller bias

 

 

 

 

 

 

 

 

 

 

 

at the time of printing is

 

 

 

 

 

 

 

 

 

 

 

displayed.

 

e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE

© June 2005 TOSHIBA TEC

2 - 84

Page 84
Image 84
Toshiba 451C, 281C, 351C manual Ate level Color 225 Bias Trailing Edge 1842-3