Toshiba 451C, 281C, 351C manual Ram

Models: 281C 351C 451C

1 200
Download 200 pages 20.21 Kb
Page 123
Image 123

 

 

Setting mode (08)

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

 

Pro-

 

 

 

Classifi-

 

Func-

<Accept-

 

 

 

 

 

 

Code

Items

RAM

 

 

Contents

cedur

 

 

 

cation

 

tion

able

 

 

 

 

e

 

 

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

561

Image

Process switching for

PPC

0

M

 

Sets whether or not

1

 

 

 

 

image smoothing (Photo)

(black)

<0-1>

 

 

performing a smooth-

 

 

 

 

 

 

 

 

 

 

ing process (primary

 

 

 

 

 

 

 

 

 

 

scanning direction,

 

 

2

562

Image

Process switching for

PPC

1

M

 

1

 

 

 

image smoothing (Text)

(black)

<0-1>

 

 

2,400 dpi or equiva-

 

 

 

 

 

 

 

 

 

 

lent).

 

 

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

 

 

1:

Valid

 

 

 

565

Image

Image quality closed-loop

ALL

1

M

 

Sets whether or not

1

 

 

 

control

control automatic start-up/

(color)

<0-2>

 

 

performing closed-loop

 

 

 

 

 

Relative humidity variation

 

 

 

 

control automatically

 

 

 

 

 

 

 

 

 

 

when the relative

 

 

 

 

 

 

 

 

 

 

humidity becomes

 

 

 

 

 

 

 

 

 

 

below the specified

 

 

 

 

 

 

 

 

 

 

level from the previous

 

 

 

 

 

 

 

 

 

 

control.

 

 

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

 

 

 

1: Valid (at mode 1)

 

 

 

 

 

 

 

 

 

 

2: Valid (at mode 2)

 

 

 

566

Image

Image quality closed-loop

ALL

1

M

 

Sets whether or not

1

 

 

 

control

control automatic start-up/

(color)

<0-2>

 

 

performing closed-loop

 

 

 

 

 

Period of time unattended

 

 

 

 

control automatically

 

 

 

 

 

 

 

 

 

 

when the equipment

 

 

 

 

 

 

 

 

 

 

has not been used for a

 

 

 

 

 

 

 

 

 

 

specified period of time.

 

 

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

 

 

 

1: Valid (at mode 1)

 

 

 

 

 

 

 

 

 

 

2: Valid (at mode 2)

 

 

 

567

Image

Image quality closed-loop

ALL

2

M

 

Sets whether or not

1

 

 

 

control

control automatic start-up/

(color)

<0-2>

 

 

performing closed-loop

 

 

 

 

 

Accumulated print volume

 

 

 

 

control automatically

 

 

 

 

 

 

 

 

 

 

when the specified

 

 

 

 

 

 

 

 

 

 

number of sheets has

 

 

 

 

 

 

 

 

 

 

been printed out from

 

 

 

 

 

 

 

 

 

 

the previous control.

 

 

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

 

 

 

1: Valid (at mode 1)

 

 

 

 

 

 

 

 

 

 

2: Valid (at mode 2)

 

 

 

568

Image

Image quality closed-loop

ALL

2

M

 

Sets whether or not

1

 

 

 

control

control automatic start-up/

(color)

<0-2>

 

 

performing closed-loop

 

 

 

 

 

When recovered from

 

 

 

 

control automatically

 

 

 

 

 

“Toner empty”

 

 

 

 

when recovered from

 

 

 

 

 

 

 

 

 

 

“Toner empty”.

 

 

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

 

 

 

1: Valid (at mode 1)

 

 

 

 

 

 

 

 

 

 

2: Valid (at mode 2)

 

 

 

© June 2005 TOSHIBA TEC

e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE

2 - 123

Page 123
Image 123
Toshiba 451C, 281C, 351C manual Ram