Adjustment mode (05)

 

 

 

 

 

 

 

Default

 

 

Pro-

 

Classifi-

 

 

 

 

Func-

<Accept-

 

 

Code

Items

 

RAM

Contents

cedur

 

cation

 

 

 

 

tion

able

 

 

e

 

 

 

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

 

367

RADF

RADF original guide width

ALL

-

-

Stores the current width

6

 

 

adjustment

 

 

 

 

of RADF original guide

 

 

 

(Minimum)

 

 

 

 

by keying in this code

 

 

 

 

 

 

 

 

 

 

with the guide set at the

 

 

 

 

 

 

 

 

 

 

minimum width. Per-

 

 

 

 

 

 

 

 

 

 

form this adjustment

 

 

 

 

 

 

 

 

 

 

when the RADF board

 

 

 

 

 

 

 

 

 

 

or volume is replaced,

 

 

 

 

 

 

 

 

 

 

or when the code (05-

 

 

 

 

 

 

 

 

 

 

356) is performed.

 

368

RADF

RADF original guide width

ALL

-

-

Stores the current width

6

 

 

adjustment

 

 

 

 

of RADF original guide

 

 

 

(Maximum)

 

 

 

 

by keying in this code

 

 

 

 

 

 

 

 

 

 

with the guide set at the

 

 

 

 

 

 

 

 

 

 

maximum width. Per-

 

 

 

 

 

 

 

 

 

 

form this adjustment

 

 

 

 

 

 

 

 

 

 

when the RADF board

 

 

 

 

 

 

 

 

 

 

or volume is replaced,

 

 

 

 

 

 

 

 

 

 

or when the code (05-

 

 

 

 

 

 

 

 

 

 

356) is performed.

 

372

Image

Black developer bias DC

ALL

100

M

Transformer output cali-

1

 

control

(-) calibration voltage 1

 

<70-130>

 

bration of the black

 

 

 

(low)

 

 

 

 

developer bias. When

 

373

Image

Black developer bias DC

ALL

900

M

replacing the high-volt-

1

 

control

(-) calibration voltage 2

 

<810-

 

age transformer, the

 

 

 

(high)

 

 

990>

 

values listed in attached

 

 

 

 

 

 

 

 

 

 

data sheet are entered.

 

 

 

 

 

 

 

 

 

 

(Unit: V)

 

380-0

Image

Image quality

 

Y

ALL

320

M

Displays the contrast

10

 

control

open-loop

 

 

 

<0-999>

 

voltage initial value set

 

 

 

control/ con-

 

 

 

 

 

 

by the open-loop con-

 

380-1

 

 

 

M

ALL

330

M

10

 

 

trast voltage

 

 

 

<0-999>

 

trol. (Unit: V)

 

 

 

initial value

 

 

 

 

 

 

 

 

380-2

 

 

 

C

ALL

340

M

 

10

 

display

 

 

 

 

 

 

 

<0-999>

 

 

 

 

 

 

 

 

 

 

 

 

 

380-3

 

 

 

 

K

ALL

375

M

 

10

 

 

 

 

 

 

 

<0-999>

 

 

 

381-0

Image

Contrast volt-

 

Y

ALL

320

M

Displays the contrast

10

 

control

age actual

 

 

 

<0-999>

 

voltage when printing is

 

 

 

value display

 

 

 

 

 

 

operated. (Unit: V)

 

381-1

 

 

 

M

ALL

330

M

10

 

 

 

 

 

 

 

<0-999>

 

 

 

381-2

 

 

 

 

C

ALL

340

M

 

10

 

 

 

 

 

 

 

<0-999>

 

 

 

381-3

 

 

 

 

K

ALL

375

M

 

10

 

 

 

 

 

 

 

<0-999>

 

 

 

382-0

Image

Image quality

 

Y

ALL

408

M

Displays the laser

10

 

control

open-loop

 

 

 

<0-999>

 

power initial value set

 

 

 

control/ laser

 

 

 

 

 

 

by the open-loop con-

 

382-1

 

 

 

M

ALL

408

M

10

 

 

power initial

 

 

 

<0-999>

 

trol. (Unit: µW)

 

 

 

value display

 

 

 

 

 

 

 

 

382-2

 

 

 

C

ALL

408

M

 

10

 

 

 

 

 

 

 

<0-999>

 

 

 

382-3

 

 

 

 

K

ALL

408

M

 

10

 

 

 

 

 

 

 

<0-999>

 

 

 

e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE

© June 2005 TOSHIBA TEC

2 - 50

Page 50
Image 50