Toshiba 451C, 281C, 351C manual All Sys Off

Models: 281C 351C 451C

1 200
Download 200 pages 20.21 Kb
Page 135
Image 135

 

 

 

 

 

Setting mode (08)

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

Pro-

 

Classifi-

 

 

 

 

Func-

<Accept-

 

 

 

Code

 

Items

RAM

 

Contents

cedur

 

cation

 

 

 

 

tion

able

 

 

 

e

 

 

 

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

702

Mainte-

 

Remote-controlled service

ALL

2

SYS

0:

Valid (Remote-con-

1

 

nance

 

function

 

<0-2>

 

1:

trolled server)

 

 

 

 

 

 

 

 

 

 

Valid (L2)

 

 

 

 

 

 

 

 

 

 

2:

Invalid

 

703

Mainte-

 

Remote-controlled service

ALL

-

SYS

Maximum 256 Bytes

11

 

nance

 

HTTP server

 

 

 

 

 

 

 

 

 

URL setting

 

 

 

 

 

 

704-0

 

 

Interruption of

Copying

ALL

1

SYS

0:

Continues printing

4

 

 

 

stapling oper-

 

 

<0-1>

 

 

by switching sort

 

 

 

 

ation (no sta-

 

 

 

 

1:

setting

 

 

 

 

ple)

 

 

 

 

Interrupts printing

 

704-1

 

 

 

 

Printing /

ALL

0

SYS

0:

Continues printing

4

 

 

 

 

 

BOX print-

 

<0-1>

 

 

by switching sort

 

 

 

 

 

 

ing

 

 

 

1:

setting

 

 

 

 

 

 

 

 

 

 

Interrupts printing

 

707

Mainte-

 

Remote-controlled service

ALL

https://

SYS

Maximum 256 Bytes

11

 

nance

 

HTTP initially-registered

 

device.mf

 

 

 

 

 

 

 

server

 

p-sup-

 

 

 

 

 

 

 

URL setting

 

port.com:

 

 

 

 

 

 

 

 

 

 

 

443/

 

 

 

 

 

 

 

 

 

 

 

device/fir-

 

 

 

 

 

 

 

 

 

 

 

streg-

 

 

 

 

 

 

 

 

 

 

 

ist.ashx

 

 

 

 

710

Mainte-

 

Short time interval setting

ALL

24

SYS

Sets the time interval to

1

 

nance

 

of recovery from Emer-

 

<1-48>

 

recover from the Emer-

 

 

(Remote)

 

gency Mode

 

 

 

gency Mode to the Nor-

 

 

 

 

 

 

 

 

 

 

mal Mode.

 

 

 

 

 

 

 

 

 

 

(Unit: Hour)

 

711

Mainte-

 

Short time interval setting

ALL

60

SYS

Unit: Minute

1

 

nance

 

of Emergency Mode

 

<30-360>

 

 

 

 

715

Mainte-

 

Remote-controlled service

ALL

1230

SYS

0 (0:00) to 2359 (23:59)

1

 

nance

 

periodical polling timing

 

 

 

 

 

 

 

 

 

(Hour/Hour/Minute/Minute)

 

 

 

 

 

 

716

Mainte-

 

Remote-controlled service

ALL

0

SYS

0:

Prohibited

1

 

nance

 

Writing data of self-diag-

 

<0-1>

 

1:

Accepted

 

 

 

 

nostic code

 

 

 

 

 

 

717

Mainte-

 

Remote-controlled service

ALL

3

SYS

Unit: Minute

1

 

nance

 

response waiting time

 

<1-30>

 

 

 

 

 

 

 

(Timeout)

 

 

 

 

 

 

718

Mainte-

 

Remote-controlled service

ALL

0

SYS

0: OFF

1

 

nance

 

initial registration

 

<0-2>

 

1:

Start

 

 

 

 

 

 

 

 

 

 

2:

Only certification is

 

 

 

 

 

 

 

 

 

 

 

scanned

 

719

Mainte-

 

Remote-controlled service

ALL

-

SYS

Maximum 10 letters

11

 

nance

 

tentative password

 

 

 

 

 

 

720

Mainte-

 

Status of remote-con-

ALL

0

SYS

0:

Not registered

2

 

nance

 

trolled service initial regis-

 

<0-1>

 

1:

Registered

 

 

 

 

tration (Display only)

 

 

 

 

 

 

721

Mainte-

 

Service center call function

ALL

2

SYS

0:

OFF

1

 

nance

 

 

 

 

 

<0-2>

 

1:

Notifies all service

 

 

 

 

 

 

 

 

 

 

2:

calls

 

 

 

 

 

 

 

 

 

 

Notifies all but

 

 

 

 

 

 

 

 

 

 

 

paper jams

 

723

Mainte-

 

Service center call HTTP

ALL

-

SYS

Maximum 256 letters

11

 

nance

 

server URL setting

 

 

 

 

 

 

726

Mainte-

 

HTTP proxy setting

ALL

1

SYS

0: Valid

1

 

nance

 

 

 

 

 

<0-1>

 

1:

Invalid

 

© June 2005 TOSHIBA TEC

 

 

 

e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE

 

 

 

 

 

 

2 - 135

 

 

 

 

 

2

06/08

Page 135
Image 135