Adjustment mode (05)

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

 

Pro-

 

Classifi-

 

 

 

 

 

Func-

<Accept-

 

 

 

Code

Items

 

 

RAM

Contents

cedur

 

cation

 

 

 

 

 

tion

able

 

 

 

e

 

 

 

 

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

237-0

Transfer

2nd transfer roller bias off-

ALL

5

M

Sets the offsetting

4

 

 

setting adjustment

 

 

(black)

<0-10>

 

amount of 2nd transfer

 

237-1

 

(Thick paper 2)

 

 

ALL

5

M

roller bias.

1: -800V

4

 

 

 

 

 

 

 

(color)

<0-10>

 

0: -1,000V

 

 

 

 

 

 

 

 

 

 

 

2: -600V

3: -400 V

 

238-0

Transfer

2nd transfer roller bias off-

ALL

5

M

4

4: -200V

5: 0 V

 

 

setting adjustment

 

 

(black)

<0-10>

 

 

 

 

 

 

 

6: +200V

7: +400V

 

 

 

(Thick paper 3)

 

 

 

 

 

 

238-1

 

 

 

ALL

5

M

4

 

 

 

8: +600V

9: +800 V

 

 

 

 

 

 

 

(color)

<0-10>

 

 

 

 

 

 

 

 

 

 

10: +1,000V

 

 

239-0

Transfer

2nd transfer roller bias off-

ALL

5

M

 

 

4

 

 

setting adjustment

 

 

(black)

<0-10>

 

 

 

 

 

 

(OHP film)

 

 

 

 

 

 

 

 

239-1

 

 

 

ALL

5

M

 

 

4

 

 

 

 

 

 

 

(color)

<0-10>

 

 

 

 

241

Main

Main charger

 

Y

ALL

78

M

As the value increases,

3

 

charger

grid bias

 

 

 

 

<0-255>

 

the transformer output

 

 

 

adjustment

 

 

 

 

 

 

increases. The adjust-

 

242

 

 

 

M

ALL

84

M

3

 

 

 

 

 

 

 

 

<0-255>

 

ment value becomes

 

 

 

 

 

 

 

 

 

 

 

effective only when the

 

243

 

 

 

 

C

ALL

87

M

3

 

 

 

 

setting mode (08-549,

 

 

 

 

 

 

 

 

<0-255>

 

 

 

 

 

 

 

 

 

 

 

551, 556, 557) is 0

 

244

 

 

 

 

K

ALL

94

M

3

 

 

 

 

(invalid).

 

 

 

 

 

 

 

 

 

<0-255>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

245

Transfer

1st transfer roller bias off-

ALL

5

M

Sets the offsetting

1

 

 

setting

 

 

(black)

<0-10>

 

amount of 1st transfer

 

 

 

 

 

 

 

 

 

 

 

roller bias.

1: -400 V

 

 

 

 

 

 

 

 

 

 

 

0: -500 V

 

 

 

 

 

 

 

 

 

 

 

2: -300 V

3: -200 V

 

 

 

 

 

 

 

 

 

 

 

4: -100 V

5: 0 V

 

 

 

 

 

 

 

 

 

 

 

6: +100 V

7: +200 V

 

 

 

 

 

 

 

 

 

 

 

8: +300 V

9: +400 V

 

 

 

 

 

 

 

 

 

 

 

10: +500 V

 

 

247

Transfer

Temperature/humidity sen-

ALL

50

M

The humidity of the

2

 

 

sor Humidity display

 

<0-100>

 

inside of the equipment

 

 

 

 

 

 

 

 

 

 

 

is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

[Unit: RH%]

 

 

248

Transfer

Drum thermistor Tempera-

ALL

23

M

The ambient tempera-

2

 

 

ture displa

 

 

 

<0-100>

 

ture of the drum surface

 

 

 

 

 

 

 

 

 

 

 

is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

[Unit: °C]

 

 

250

Transfer

1st transfer

 

+Low

ALL

4000

M

Transformer output set-

1

 

 

roller bias out-

 

 

 

 

<3600-

 

ting of the 1st transfer

 

 

 

put voltage

 

 

 

 

4400>

 

roller bias.

 

 

 

 

 

 

 

 

 

 

 

 

When replacing the

 

251

 

 

 

 

+High

ALL

400

M

high-voltage trans-

1

 

 

 

 

 

 

 

 

<280-

 

former, the values listed

 

 

 

 

 

 

 

 

 

520>

 

in attached data sheet

 

 

 

 

 

 

 

 

 

 

 

are entered.

 

 

 

 

 

 

 

 

 

 

 

 

(Unit: V)

 

 

252

Transfer

2nd transfer

 

+Low

ALL

6000

M

Transformer output set-

1

 

 

roller bias out-

 

 

 

 

<5400-

 

ting of the 2nd transfer

 

 

 

put voltage

 

 

 

 

6600>

 

roller bias (plus output).

 

 

 

 

 

 

 

 

 

 

 

When replacing the

 

253

 

 

 

 

+High

ALL

500

M

high-voltage trans-

1

 

 

 

 

 

 

 

 

<350-

 

former, the values listed

 

 

 

 

 

 

 

 

 

650>

 

in attached data sheet

 

 

 

 

 

 

 

 

 

 

 

are entered.

 

 

 

 

 

 

 

 

 

 

 

 

(Unit: V)

 

 

e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE

 

 

© June 2005 TOSHIBA TEC

2 - 44

Page 44
Image 44
Toshiba 351C, 451C, 281C manual 200V Setting adjustment Black +200V +400V Thick paper 238-1