Setting mode (08)

 

 

 

 

 

 

 

 

 

Default

 

 

 

Pro-

 

Classifi-

 

 

Func-

<Accept-

 

 

 

Code

 

Items

RAM

 

Contents

cedur

 

cation

 

 

tion

able

 

 

 

e

 

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

 

678

General

 

Setting of banner advertis-

ALL

0

SYS

Sets whether or not dis-

1

 

 

 

ing display

 

<0-1>

 

playing the banner

 

 

 

 

 

 

 

 

advertising. The setting

 

 

 

 

 

 

 

 

contents of 08-679 and

 

 

 

 

 

 

 

 

08-680 are displayed at

 

 

 

 

 

 

 

 

the time display section

 

 

 

 

 

 

 

 

on the right top of the

 

 

 

 

 

 

 

 

screen. When both are

 

 

 

 

 

 

 

 

set, each content is dis-

 

 

 

 

 

 

 

 

played alternately.

 

 

 

 

 

 

 

 

0: Not displayed

 

 

 

 

 

 

 

 

1: Displayed

 

679

General

 

Banner advertising display

ALL

-

SYS

Maximum 27 letters

11

 

 

 

1

 

 

 

(one-byte character)

 

680

General

 

Banner advertising display

ALL

-

SYS

Maximum 27 letters

11

 

 

 

2

 

 

 

(one-byte character)

 

681

General

 

Display of [BANNER MES-

ALL

0

SYS

0: Not displayed

1

 

 

 

SAGE] button

 

<0-1>

 

1: Displayed

 

 

 

 

 

 

 

 

*

This button enables

 

 

 

 

 

 

 

 

 

the entry of “Banner

 

 

 

 

 

 

 

 

 

advertising display 1

 

 

 

 

 

 

 

 

 

(08-679)” and “Ban-

 

 

 

 

 

 

 

 

 

ner advertising dis-

 

 

 

 

 

 

 

 

 

play 2 (08-680)” on

 

 

 

 

 

 

 

 

 

the control panel.

 

682

Use

 

Offsetting between jobs

ALL

1

SYS

0: Invalid

1

 

interface

 

 

 

<0-1>

 

1: Valid

 

683

General

 

Duplex printing setting

ALL

1

SYS

When the duplex print-

1

 

 

 

when coin controller is

 

<0-1>

 

ing is short paid with a

 

 

 

 

used

 

 

 

coin controller, reverse

 

 

 

 

 

 

 

 

side of the original is

 

 

 

 

 

 

 

 

not printed and is con-

 

 

 

 

 

 

 

 

sidered as a defect

 

 

 

 

 

 

 

 

(printing job may be

 

 

 

 

 

 

 

 

cleared). To solve this

 

 

 

 

 

 

 

 

problem, the selection

 

 

 

 

 

 

 

 

of printing method is

 

 

 

 

 

 

 

 

enabled with this set-

 

 

 

 

 

 

 

 

ting.

 

 

 

 

 

 

 

 

0:

Invalid (Both sides

 

 

 

 

 

 

 

 

 

printed)

 

 

 

 

 

 

 

 

1: Valid (Only one side

 

 

 

 

 

 

 

 

 

printed)

 

684

General

 

Rebuilding all databases

ALL

-

SYS

Rebuilds all databases.

3

685

General

 

Rebuilding all databases

ALL

-

SYS

Rebuilds all databases

3

 

 

 

related to Address Book

 

 

 

related to the Address

 

 

 

 

 

 

 

 

Book.

 

686

General

 

Rebuilding all databases

ALL

-

SYS

Rebuilds all databases

3

 

 

 

related to log

 

 

 

related to the logs.

 

689

FAX

 

Adaptation of paper source

FAX

0

SYS

0: Not subjected for

1

 

 

 

priority selection

 

<0-1>

 

 

APS judgment

 

 

 

 

 

 

 

 

1: Subjected for APS

 

 

 

 

 

 

 

 

 

judgment

 

690

General

 

HDD formatting

ALL

-

SYS

2: Normal formatting

7

 

 

 

 

 

<2>

 

 

 

 

691

General

 

HDD type display

ALL

-

SYS

0: Not formatted

7

 

 

 

 

 

<0-2>

 

1: Not used

 

 

 

 

 

 

 

 

2:

Normal format

 

© June 2005 TOSHIBA TEC

 