Setting mode (08)

 

 

 

 

 

 

 

 

Default

 

 

 

Pro-

Code

Classifi-

 

Func-

<Accept-

 

 

 

Items

RAM

 

Contents

cedur

 

cation

 

tion

able

 

 

 

e

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

348

Counter

Count setting of thick paper

ALL

1

M

0: Counted as 1

1

 

 

(PM)

 

<0-1>

 

1: Counted as 2

 

349

Counter

Count setting of OHP film

ALL

1

M

0: Counted as 1

1

 

 

(PM)

 

<0-1>

 

1: Counted as 2

 

352

Counter

Count setting of large-

ALL

JPN: 0

M

0: Counted as 1

1

 

 

sized paper (Fee charging

 

OTHER:

 

1: Counted as 2

 

 

 

system counter)

 

1

 

2: Counted as 1

 

 

 

 

 

<0-2>

 

 

(Mechanical counter

 

 

 

 

 

 

 

 

is double counter)

 

353

Counter

Definition setting of large-

ALL

0

M

0:

A3/LD

1

 

 

sized paper (Fee charging

 

<0-1>

 

1: A3/LD/B4/LG/

 

 

 

system counter)

 

 

 

 

FOLIO/COMP/8k

 

356

Counter

Counter for upper drawer

ALL

0

M

Counts the number of

2

 

 

feeding

 

<8 digits>

 

sheets fed from upper

 

 

 

 

 

 

 

drawer

 

357

Counter

Counter for lower drawer

ALL

0

M

Counts the number of

2

 

 

feeding

 

<8 digits>

 

sheets fed from lower

 

 

 

 

 

 

 

drawer

 

358

Counter

Counter for bypass feeding

ALL

0

M

Counts the number of

2

 

 

 

 

<8 digits>

 

sheets fed from bypass

 

 

 

 

 

 

 

feed

 

359

Counter

Counter for LCF feeding

ALL

0

M

Counts the number of

2

 

 

 

 

<8 digits>

 

sheets fed from LCF

 

360

Counter

Counter for PFP upper

ALL

0

M

Counts the number of

2

 

 

drawer feeding

 

<8 digits>

 

sheets fed from PFP

 

 

 

 

 

 

 

upper drawer

 

370

Counter

Counter for PFP lower

ALL

0

M

Counts the number of

2

 

 

drawer feeding

 

<8 digits>

 

sheets fed from PFP

 

 

 

 

 

 

 

lower drawer

 

372

Counter

Counter for ADU

ALL

0

M

Counts the number of

2

 

 

 

 

<8 digits>

 

output pages of duplex

 

 

 

 

 

 

 

printing.

 

374

Counter

Counter for RADF

ALL

0

SYS

Counts the number of

2

 

 

 

 

<8 digits>

 

originals fed from RADF

 

375

Mainte-

Setting value of PM time

ALL

Refer to

M

<Default>

1

 

nance

counter display/0 clearing

 

content

 

e-STUDIO281c

 

 

 

 

 

<8 digits>

 

 

JPN:0

 

 

 

 

 

 

 

 

UC, EUR: 315,000

 

 

 

 

 

 

 

e-STUDIO351c

 

 

 

 

 

 

 

 

JPN:0

 

 

 

 

 

 

 

 

UC, EUR: 315,000

 

 

 

 

 

 

 

e-STUDIO451c

 

 

 

 

 

 

 

 

JPN: 0

 

 

 

 

 

 

 

 

UC, EUR: 315,000

 

376

Mainte-

Current value of PM time

ALL

0

M

Counts the drum driving

1

 

nance

counter

 

<8 digits>

 

time (main motor ON).

 

381

Counter

Setting for counter installed

ALL

1

M

Selects the job to count

1

 

 

externally

 

<0-7>

 

up for the external

 

 

 

 

 

 

 

counter.

 

 

 

 

 

 

 

0:

Not selected

 

 

 

 

 

 

 

1:

Copier

 

 

 

 

 

 

 

2:

FAX

 

 

 

 

 

 

 

3:

Copier/FAX

 

 

 

 

 

 

 

4:

Printer

 

 

 

 

 

 

 

5:

Copier/Printer

 

 

 

 

 

 

 

6:

Printer/FAX

 

 

 

 

 

 

 

7:

Copier/Printer/FAX

 

e-STUDIO281c/351c/451c ERROR CODE AND SELF-DIAGNOSTIC MODE

 

 

 

© June 2005 TOSHIBA TEC

2 - 112

Page 112
Image 112
Toshiba 281C, 451C, 351C manual Other, JPN0