Setting mode (08)

 

 

 

 

Default

 

 

 

Pro-

 

Classifi-

 

Func-

<Accept-

 

 

 

Code

Items

RAM

 

Contents

cedur

 

cation

 

tion

able

 

 

 

e

 

 

 

 

value>

 

 

 

 

 

 

 

 

 

 

 

544

Image

Environment correction

ALL

1

M

Sets whether or not cor-

1

 

control

control of 2nd transfer

 

<0-1>

 

recting the 2nd transfer

 

 

 

roller bias

 

 

 

roller bias depending on

 

 

 

 

 

 

 

the environment.

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

1:

Valid

 

545

Image

Transfer belt life correction

ALL

1

M

Sets whether or not cor-

1

 

control

of 2nd transfer roller bias

 

<0-1>

 

recting the 2nd transfer

 

 

 

 

 

 

 

roller bias depending on

 

 

 

 

 

 

 

the transfer belt life.

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

1:

Valid

 

546

Image

2nd transfer roller life cor-

ALL

1

M

Sets whether or not cor-

1

 

control

rection of 2nd transfer

 

<0-1>

 

recting the 2nd transfer

 

 

 

roller bias

 

 

 

roller bias depending on

 

 

 

 

 

 

 

the 2nd transfer roller

 

 

 

 

 

 

 

life.

Invalid

 

 

 

 

 

 

 

0:

 

 

 

 

 

 

 

1:

Valid

 

548

Transfer

Setting of 2nd transfer

ALL

EUR:0

M

0:80 g/m2 (21.3 lb.)/

1

 

 

roller bias table (for each

 

UC:1

 

EUR

 

 

 

destination/paper thick-

 

JPN:2

 

1:

75 g/m2 (20 lb.)/UC

 

 

 

ness)

 

<0-2>

 

2: 64 g/m2 (17.1 lb.)/

 

 

 

 

 

 

 

 

JPN

 

549

Image

Image quality control/open-

ALL

1

M

Sets whether or not

1

 

control

loop control 1

 

<0-1>

 

performing the open-

 

 

 

 

 

 

 

loop control 1.The

 

 

 

 

 

 

 

open-loop control 1 is

 

 

 

 

 

 

 

performed in advance

 

 

 

 

 

 

 

of the closed-loop con-

 

 

 

 

 

 

 

trol.

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

1:

Valid

 

550

Image

Default setting of Original

PPC

0

SYS

0:

Text/Photo

1

 

 

mode

(black)

<0-3>

 

1:

Photo

 

 

 

 

 

 

 

2:

Text

 

 

 

 

 

 

 

3: Gray Scale

 

551

Image

Image quality control/open-

ALL

1

M

Sets whether or not

1

 

control

loop control 2

 

<0-1>

 

performing the open-

 

 

 

 

 

 

 

loop control 2.The

 

 

 

 

 

 

 

open-loop control 2 is

 

 

 

 

 

 

 

performed before or

 

 

 

 

 

 

 

during printing.

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

1:

Valid

 

552

Image

Drum life correction control

ALL

1

M

Sets whether or not cor-

1

 

control

 

 

<0-1>

 

recting the drum volt-

 

 

 

 

 

 

 

age depending on the

 

 

 

 

 

 

 

drum life in open-loop

 

 

 

 

 

 

 

control.

 

 

 

 

 

 

 

0:

Invalid

 

 

 

 

 

 

 

1:

Valid

 