A-4 Appendix A
Note: All downstream devices must be set to 6180 speed and use 61 80
profiles regardless of the speed of the Host Printer.
Add 2200 to the Sheet Jam time and 2600 to the Set Jam time of
the downstream device’s profile, even if you have more than one
GBC Bypass Stacker installed. Be sure to add any extra tim es
specified by their profiles.
Note: N.B.:(C.P. Bourg)
nIf one or more High Capacity Stackers is used, do not forget to
add 656ms to the Sheet and Set Jam times for each stacker,
when connected on a 6180 upstream or downstream. Add
861ms, when connected on a 6135 upstream only.
nHigh Capacity Stacker software must be 3.5.2
(DFA+Input+Driver) to support Cycle up and T.E. Signals from
printer.
nBPRF+BBF2005: control of milling motor by BPRF requires:
-Cycle up from printer + BPRF ready in perf. mode, if
connected on a 61xx printer (PLC input X17 <ON>).
-BPRF ready in perf. mode, if connected (BBF2005 PLC inputs
X17/18/19 <OFF>).
nDelivery End Adjust: to allow th e BPRF to determine if C0/C1
are trigged <Lead < or <Trail> edge, the m aximum C0 pulse
duration in <Trail> edge must be limited at 60 ms. In <Lead>
edge mode, the C0 pulse duration is a function of the sheet size
(process direction at pronter output) and is always longer than
100ms.
nBCFX: Maximum cover width (cross process direction):
310mm; minimum cover lenght (process direction): 250mm;
maximum document width (bypass through BCFX): 310mm.