84 Additional options
Reverberation results
Models SE and DL
studies, you may want to review the data at the end of the session. In this
example, you would access the File\Session\Data F ile screen and select a
past study. (For more information, see “Viewing past s essions/studies” in
Chapter 7.)
RT60 summary screen
This is a vertical bar chart that will plot the T60 va lues taken from each octave
band or 1/3 octave band.
Viewing RT60 values of each band
1. The decay value for each specific band is viewabl e by pressing the
left/right arrow keys.
NOTE: Bands with invalid T60 values will show dashes (---) instead of a
value.
Figure 6-5: RT60 bar chart screen
Deleting RT60 value in a filtered band
This optional feature allows you to delete a selected f iltered band from the
session average and is available when in review m ode of “view current study”
screens. (This may be used, if for example, you had someone accidentally
walk in during your test and begin speaking. You c ould delete the bands
which interfered with your test from the RT60 average results .)
1. To delete a filtered band, select either the RT60 S ummary screen or the
Decay curve screen.
Filter band results
Displays the RT60 filter
band frequency values
T
60(20)
States that T60
measurement was
extrapolated from a
T20 measure.
Overall RT60 value of
selected band.
Selected band
RT60 bar chart
Decay (To view decay
results, press softkey)