Basic setups

Measurement setup (for community noise)

NOTE: For quick and easy access, there are three optional screens to change the timed response and the weighting. These are in the following SoundPro screens: Measures Set screen, View Current Study screen, and View Session study screen.

Measurement setup (for community noise)

The measure screen is used to select community noise settings for meter 1 only. Table 3-2 below explains the settings and options.

Setting up community noise measurements (refer to figure 3-5 below)

1.Ensure you are at the start screen.

If turned on, repeatedly press On/Off/Esc until you return to the start screen (see Figure 3-3).

2.Press Up/Down to highlight Setup and then press Enter .

3.Select Measures from the Setup screen by pressing Up/Down to

highlight and then press Enter .

4.In the Measures screen, press Up/Down to select one of the measurements. To select second column, first press Up/Down arrows then press Right arrow.

Measurements

L1-L4

LDN, CNEL

Lc-a, TAKTMX

1

2Data fields

Edit column 1 or column 2 fields by pressing enter repeatedly to toggle through selections.

Figure 3-5: Measures screen for community noise settings

5.To make changes to the data fields, do one of the following:

L1-L4- Press Enter to move to the data field. In the data field, repeatedly press Enter to change your selection.

Press arrows to change percentage.

LDN - Press Enter to move to data field and continue to press Enter to toggle between On/Off setting.

Models SE and DL

Page 41