29

Basic setups

Measurement setup (for community noise)

CNEL – Press Enter to select data field. Press Enter repeatedly to toggle between On/Off setting.

Lc-a– Press Enter to select data field. If marked “N/A,” see “C- A measurement settings.”

TAKTMX ~ Press Enter one or more times to select 3 sec., 5 sec., or Off.

6.To change other measurement settings, repeat steps 4-5.

7.When finished, press On/Off/Esc to exit the screen.

The following table explains your selections in the Measures screen

(Please see Appendix B, Glossary of Terms for more details.)

Measurements Explanation

L1-L4L1-L4 are types of exceedance levels. This is defined as the

(Exceedance) level exceeded by the measured noise level for an identified fraction of time. Exceedance levels may be calculated for many time fractions (or percentages).

 

 

Optional Settings: Set to “Off” or to a percentage value of

 

 

 

 

your choice (1-99%).

 

LDN

 

Representing the Day/Night sound level, this measurement is

 

 

 

24-hour average sound level where 10 dB is added to all of the

 

 

 

readings that occur between 10pm to 7am. (Please see

 

 

 

glossary of terms for more details).

 

 

 

Optional Settings: Set to “Off” or “On”.

 

CNEL

 

Community Noise Exposure Level. The accumulated exposure

 

 

 

to sound measured in 24-hour sampling interval and artificially

 

 

 

boosted during certain hours.

 

 

 

Optional Settings: Set to “Off” or “On”.

 

Lc-a

 

This measurement (also commonly called C-A measurement) is

 

 

 

only available under certain conditions. Information about

 

 

 

viewing and changing these meter settings is discussed under

 

 

 

the next section, “C-A measurement settings”. Optional

 

 

 

Settings: Set to “On” and “Off”. See C-A section below for

 

 

 

parameter settings.

 

TAKTMX

 

A time average over a sampling that uses the highest level

 

 

 

occurring during the preceding Taktmaximal interval (either

 

 

 

three or five seconds), and assumes it was present for the

 

 

 

whole Taktmx interval.

 

 

 

Optional Settings: Set to “Off”, “3sec”, or “5sec”

 

 

 

 

 

 

 

Table 3-2: Measures screen explained

 

Models SE and DL

Page 42
Image 42
3M SE, DL user manual Measurements Explanation, Measures screen explained