Chapter 5: Setting Up Your Cash Register - Advanced
Setting the Amount of Time Letters Appear in the Display
You can specify the amount of time letters appear in the display. The shorter amount of time, the faster the message scrolls across the display.
To program the amount of time letters appears
1Put the PRG key in the Mode key slot and turn it to the PRG position.
2If you are prompted for a Manager Password, type the password number and then press the Check key. If you did not program a Manager Password, go to the next step.
3Using the round Number keys, press 70. Press one digit number from the chart below, representing the number of seconds you want to delay, and press the Charge key.
Press this number... | To specify... |
| |
|
|
| |
0 | 0.2 seconds | Fast | |
1 | 0.3 |
|
|
2 | 0.4 | - Default |
|
3 | 0.5 |
|
|
4 | 0.6 |
|
|
5 | 0.7 |
|
|
6 | 0.8 |
|
|
7 | 0.9 |
|
|
8 | 1.0 |
| Slow |
Programming the Credit Keys
You can use 2 department keys as credit
When you ring up a sale, you can use Department 19 or Department 20 to finalize the credit card sale, open the cash drawer, and print the receipt or journal tape.
You must set Flag 16 Option Number 1, 2, or 3 to use this feature. For more information about setting Flags, see Programming Flag Options on page 56.
46 | Alpha 583cx User’s Guide |