The Agilent Technologies Infiniium Oscilloscope Model 54835A/45A/46A at a

Glance

Ease of use with high performance

The Agilent Technologies Infiniium oscilloscopes combine unprecedented ease-of-use with high- performance digitizing oscilloscope functionality to simplify your design and analysis measurement tasks.

Traditional oscilloscope front-panel interface provides direct access to the controls needed for most troubleshooting tasks

Graphical user interface with menus, windows, dialogs, and toolbars provides easy access to dozens of configuration and analysis tools, ensuring you can set up and make the most complex measurements

Agilent 54835A offers 4 channels, 4 GSa/s sampling rate in 2-channel mode, 2 GSa/s sampling rate in 4-channel mode, 1 GHz bandwidth

Agilent 54845A offers 4 channels, 8 GSa/s sampling rate in 2-channel mode, 4 GSa/s sampling rate in 4-channel mode, 1.5 GHz bandwidth

Agilent 54846A offers 4 channels, 8 GSa/s sampling rate in 2-channel mode, 4 GSa/s sampling rate in 4-channel mode, 2.25 GHz bandwidth

Display shows waveforms and graphical user interface

Graphical interface allows direct interaction with waveforms, including drag-and-drop positioning and instant waveform zoom

Waveforms displayed in color, making correlation easy

Current configuration parameters displayed near the waveform display and are color- coded to make identification easy

Graphical interface menus and toolbars simplify complex measurement setups

Horizontal controls set sweep speed and position

Main sweep speeds from 100 ps/div to 5 s/div

Delayed sweep speeds from 1 ps/div to main time base setting

Intensified waveforms on main sweep window make it easy to see what will appear in delayed sweep window

Acquisition and general controls start and stop the scope and do basic setup

Run and stop controls for continuous or single-shot acquisitions

Clear display before one or more acquisitions

Default setup and Autoscale set initial configuration

Hard disk drive and floppy disk drive for saving and restoring setups and measurement results

Store measurement displays for inclusion in reports and test setup guides

Store oscilloscope setups to repeat tests another time

Hard disk stores oscilloscope operating system

Trigger setup controls set mode and basic parameters

Select Edge, Glitch, or Advanced Modes

Choose input source and slope

Set coupling for trigger

Use graphical user interface to simplify configuration of pattern, state, delay, violation, and video triggers

Use auxiliary trigger to increase triggering flexibility

Vertical controls set input coupling, impedance, attenuation, and position

AC or DC input coupling

1 Mor 50input impedance

Input attenuation adjustable from 2 mV/div to 1 V/div (plus 2 V/div in 1 M)

Color-coded knobs make it easy to find the controls that affect each waveform

Marker and quick measurements help measure waveform parameters

Waveform markers A and B to check voltage or ∆−time at any point on the displayed waveform

Quick Meas executes up to four predefined measurements instantly

Service Policy

The service policy of this instrument requires replacing defective assemblies. Some assemblies can be replaced on an exchange basis. Items such as the vertical attenuators, which are subject to wear and tear based on frequency of use, are a maintenance item that may need occasional replacement.