The DGCL Recognition feature gives the user the ability to enable and disable recognition of the Datasouth Graphics Command Language. When the feature is ‘enabled’, the DGCL entrance command ‘^PY’ will be recognized and executed thus giving the user access to all the DGCL commands. When the feature is ‘disabled’, the DGCL entrance command ‘^PY’ will be ignored thus locking out user access to the DGCL mode. Under this condition all DGCL data will be passed on to the active emulation mode command processor and handled in a manner consistent with that active emulation mode.

The ‘Default Command Character’ feature gives the user the ability to select the default command character for the DGCL mode. The command character is the leading character in any valid DGCL command sequence. Valid selectable command characters would be any printable ASCII code between 33 and 255.

The ‘One Dot Barcode Overlap’ feature will give the user the ability to overlap the different passes of a barcode symbol by one dot.

The ‘DGCL Exit Mode’ feature gives the user the ability to select 1 of 4 exit modes.

NOTE

The up caret character (^) is the command character used to introduce a DGCL command sequence and does not represent the control key. This character cannot be printed in DGCL mode unless you change the command character with the ^N command. The default value of the command character is determined by the ‘Default Command Character’ feature. It will be assumed throughout the remainder of this specification, that the default command character is the ‘^’ character.

H-2 Transparency Mode

Page 208
Image 208
AMT Datasouth 3300 manual Transparency Mode