4.Insert the AXM-CV(/PB) or AXM-CA(/PB) into the rack. Line up the top left and right screw holes and start the #6-32 screws. Then, start the bottom left and right screws. Tighten all the screws after you start all the screws.
5.Connect the AXlink wiring to the AMX Central Controller and RS-232 wiring to the external RS-232 device. The AXM-CV(/PB) or AXM-CA(/PB) will beep when you apply power.
Wiring the Touch Panels
The CATPs use a four-pin AXlink connector for power and data. Figure 11 shows the rear panel AXlink connector on the TiltScreen color active and color video touch panels. Figure 12 shows the rear panel AXlink connector on the UniMount and rack-mount color active and color video touch panels.
Figure11
TiltScreen Color and Video Touch Panel connectors (rear view)
Figure12
Rack-Mount CATP connectors (top view)
Rear view
Video models only
4-pin (male) AXlink connector
RS-232 (male) connector | RCA Video connector - video |
|
| models only |
| Top view |
Caution
Do not connect power to the Touch Panel until the wiring is complete. If you are using a 12 VDC power supply, apply power to the Touch Panel only after installation is complete.
Preparing captive wires
You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.
1.Strip 0.25 inch (6.35 mm) of wire insulation off all wires.
Color Active-Matrix LCD Touch Panels | Installing Touch Panels | 13 |