Programming

 

 

Button Query Commands (Cont.)

 

 

 

 

 

 

 

 

?BOP

Syntax:

 

 

 

Get the overall

"'?BOP-<vt addr range>,<button states range>'"

 

 

 

button opacity.

Variable:

 

 

 

 

variable text address range = 1 - 4000.

 

 

 

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

 

 

 

1 = Off state and 2 = On state).

 

 

 

 

custom event type 1015:

 

 

 

 

Flag - Zero

 

 

 

 

Value1 - Button state number

 

 

 

 

Value2 - Opacity

 

 

 

 

Value3 - Zero

 

 

 

 

Text - Blank

 

 

 

 

Text length - Zero

 

 

 

 

Example:

 

 

 

 

SEND COMMAND Panel,"'?BOP-529,1'"

 

 

 

 

Gets the button 'OFF state' opacity information.

 

 

 

 

The result sent to the Master would be:

 

 

 

 

ButtonGet Id = 529 Type = 1015

 

 

 

 

Flag = 0

 

 

 

 

VALUE1 = 1

 

 

 

 

VALUE2 = 200

 

 

 

 

VALUE3 = 0

 

 

 

 

TEXT =

 

 

 

 

TEXT LENGTH = 0

 

 

 

 

 

 

 

 

?BRD

Syntax:

 

 

 

Get the current

"'?BRD-<vt addr range>,<button states range>'"

 

 

 

border name.

Variable:

 

 

 

 

variable text address range = 1 - 4000.

 

 

 

 

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

 

 

 

1 = Off state and 2 = On state).

 

 

 

 

custom event type 1014:

 

 

 

 

Flag - Zero

 

 

 

 

Value1 - Button state number

 

 

 

 

Value2 - Actual length of string

 

 

 

 

Value3 - Zero

 

 

 

 

Text - String that represents border name

 

 

 

 

Text length - Border name length

 

 

 

 

Example:

 

 

 

 

SEND COMMAND Panel,"'?BRD-529,1'"

 

 

 

 

Gets the button 'OFF state' border information.

 

 

 

 

The result sent to the Master would be:

 

 

 

 

ButtonGet Id = 529 Type = 1014

 

 

 

 

Flag = 0

 

 

 

 

VALUE1 = 1

 

 

 

 

VALUE2 = 22

 

 

 

 

VALUE3 = 0

 

 

 

 

TEXT = Double Bevel Raised -L

 

 

 

 

TEXT LENGTH = 22

 

 

 

 

 

 

 

 

?BRT

Syntax:

 

 

 

Get the Panel

BRIT/@BRT-<brightness value>

 

 

 

Brightness value

Variable:

 

 

 

 

Value1=panel brightness value

 

 

130

 

 

 

 

 

MVP-8400i 8.4" Modero® ViewPoint® Touch Panel with Intercom

 

 

 

 

 

 

 

Page 144
Image 144
AMX MVP-8400i manual ?Bop, ?Brd, ?Brt