Setup Pages

System Settings Page Elements

Master Connection (Cont.):

 

 

Mode

 

Cycles between the connection modes: URL, Listen, and Auto.

 

(Ethernet Only - disabled when USB is selected)

 

URL - In this mode, enter the IP/URL, Master Port Number, and

 

 

username/password (if used) on the Master. The System Number field is

 

 

read-only - the panel obtains this information from the Master.

 

Listen - In this mode, add the panel address into the URL List in NetLinx

 

 

Studio and set the connection mode to Listen. This mode allows the

 

 

Modero touch panel to “listen” for the Master’s communication signals.

 

 

The System Number and Master IP/URL fields are read-only.

 

Auto - In this mode, enter the System Number and a username/password

 

 

(if applicable). Use this mode when both the panel and the NetLinx Master

 

 

are on the same Subnet, and the Master has its UDP feature enabled. The

 

 

Master IP/URL field is read-only.

System Number

 

Allows you to enter a system number. Default value is 0 (zero).

 

(ETHERNET Only - disabled when USB is selected)

Master IP/URL

 

Sets the Master IP or URL of the NetLinx Master.

 

(ETHERNET Only - disabled when USB is selected)

Master Port Number

 

Allows you to enter the port number used with the NetLinx Master.

 

Default = 1319

 

(ETHERNET Only - disabled when USB is selected)

Username/Password

 

If the target Master has been previously secured, enter the alpha-numeric string

 

(into each field) assigned to a pre-configured user profile on the Master. This

 

profile should have the pre-defined level of access/configuration rights.

 

 

 

Refer to the Step 3: Choose a Master Connection Mode section on page 24 for more detailed information on using the

System Settings page.

56

MVP-8400i 8.4" Modero® ViewPoint® Touch Panel with Intercom

Page 70
Image 70
AMX MVP-8400i manual System Settings