Testing the complete configuration
Testing port network equipment
These tests verify that the time division multiplexing (TDM) cables and terminators work. If a FAIL Result code is seen, check these cables. If problems persist, see the maintenance book for your configuration.
Checking port network status for each media gateway
The port network status may suggest problem areas. Tests described later provide more specific diagnostic information.
To check the port network status for each media gateway:
1.Type status port-network number <1-64> and press Enter.
2.Verify the screen displays a Port Network Status screen similar to Figure 60: Sample port network status screen for Cabinet
Verify these service states:
Field | Service State |
|
|
TDM Bus A | in |
|
|
TDM Bus B | in |
|
|
Tone/Clock | in |
|
|
PKT | in |
|
|